INSTALLATION - ASSEMBLY INSTRUCTIONS
Install the hood away from very dirty locations, windows, doors and sources of heat.
Expansion plugs are provided to secure the hood to most types of ceilings. However, a qualified technician is needed to make
sure that the plugs are suitable for your ceiling. The wall/ceiling must be strong enough to take the weight of the hood.
REFER TO FIG. 1
• Trace a centre line on the wall (1), position the drilling template on it so that the central line printed on the template
matches the central line marked on the wall and the bottom part of the template is aligned with the bottom of the hood
when mounted (2).
• Drill 3 holes Ø 8 mm and fix the support bracket to the wall using 2 wall plugs and 2 screws (3). Insert the third wall plug in
the bottom hole.
• Remove the drilling template from the wall, hang the hood (4), adjust its position (5-6) and fix it with 1 screw and 1 washer
(7).
• Disconnect the power at the house main switch before electrically connecting the hood (8).
• Fit the air outlet protection (9) to the hood air outlet.
• Fit the deflector (9) to the hood outlet.
• Fit the grease filters, complete with carbon filter, and close the front panel (see the section "Fitting the carbon filter").
• Reconnect the power at the house main switch.
Adjacent wall
units
5019 318 33308
Installation dimensions
Central line
65 cm (gas or combi cookers)
45 cm (electric cookers)
Cooktop surface