Venting & air — general
Venting and air piping — DIRECT VENT ONLY — OPTIONS and PIPING LIMITS
The table below lists the acceptable vent/air pipe terminations described in this manual. Follow all instructions provided to install the
vent/air system.
For these applications, use ONLY the manufacturers' parts listed and follow all instructions provided by the pipe manufacturer.
(All applications include allowance for the termination fittings plus one elbow in air piping and one elbow in vent piping).
See Figure 27, page 23 for material specifications | See Figure 125, page 137 for part/kit numbers
If using 2" pipe, provide 3"x 2" tapered reducers at boiler connections and at Weil-McLain vent/air cap or at concentric terminations.
Boilers will derate as vent/air pipe length increases — see rating data on Figure 138, page 149 for derate amounts.
Separate pipes
[Note 1]
See page 28
Size,
Materials
inches
Fig. 27, page 23
PVC/PVC-DWV
2
CPVC, PP, SS
80/110
PVC/PVC-DWV
3
CPVC, PP, SS
PVC/PVC-DWV
2
CPVC, PP, SS
150
PVC/PVC-DWV
3
CPVC, PP, SS
2
CPVC, PP, SS
199
PVC/PVC-DWV
3
CPVC, PP, SS
Equivalent feet for elbows (USE SWEEP ELBOWS ONLY) — deduct from max. equivalent length of piping (does not apply to termination fittings).
PVC
PP & SS
Note 1:
Note 2:
22
below, but also approved, are the polypropylene piping and terminations listed in Figure 27, page 23.
Maximum vent and air pipe length (for each)
80/110/150 - 2" & 3" = 100 feet
199 - 3" = 100 feet / 199 -2" = 50 feet
(Minimum length for all applications is 2 feet)
Vent and air pipe sizes:
Maximum vent lengths apply for either 2" or 3" vent and air pipe.
SIDEWALL termination
PVC or PP Concentric
3" Weil-McLain PVC
[Note 1 & 2]
vent/air cap [
See page 30
See page 32
Size,
Materials
Size,
inches
Fig. 27, page 23
inches
Fig. 27, page 23
PVC/PVC-DWV
PVC/PVC-DWV
2
2
CPVC, PP, SS
PVC/PVC-DWV
PVC/PVC-DWV
3
3
CPVC, PP, SS
PVC/PVC-DWV
PVC/PVC-DWV
2
2
CPVC, PP, SS
PVC/PVC-DWV
PVC/PVC-DWV
3
3
CPVC, PP, SS
2
2
CPVC, PP, SS
PVC/PVC-DWV
PVC/PVC-DWV
3
3
CPVC, PP, SS
80/110/150/199
(continued)
Separate pipes
]
[Note 1]
Note 1 & 2
See page 34
Materials
Size,
Materials
inches
Fig. 27, page 23
PVC/PVC-DWV
2
CPVC, PP, SS
CPVC, PP, SS
PVC/PVC-DWV
3
CPVC, PP, SS
CPVC, PP, SS
PVC/PVC-DWV
2
CPVC, PP, SS
CPVC, PP, SS
PVC/PVC-DWV
3
CPVC, PP, SS
CPVC, PP, SS
2
CPVC, PP, SS
CPVC, PP, SS
PVC/PVC-DWV
3
CPVC, PP, SS
CPVC, PP, SS
B
M
OILER
ANUAL
SWEEP
ELBOWS
VERTICAL termination
PVC or PP Concentric
Vertical vent,
[Note 1 & 2]
Side Air [Note 1]
See page 36
See page 38
Size,
Materials
Size,
inches
Fig. 27, page 23
inches
PVC/PVC-DWV
2
2
CPVC, PP, SS
PVC/PVC-DWV
3
3
CPVC, PP, SS
PVC/PVC-DWV
2
2
CPVC, PP, SS
PVC/PVC-DWV
3
3
CPVC, PP, SS
2
2
CPVC, PP, SS
PVC/PVC-DWV
3
3
CPVC, PP, SS
t
Part number 550-100-260/0520
USE
ONLY
Materials
Fig. 27, page 23
PVC/PVC-DWV
CPVC, PP, SS
PVC/PVC-DWV
CPVC, PP, SS
PVC/PVC-DWV
CPVC, PP, SS
PVC/PVC-DWV
CPVC, PP, SS
CPVC, PP, SS
PVC/PVC-DWV
CPVC, PP, SS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecotec 110Ecotec 150Ecotec 199

Table of Contents