Table Of Contents - Weil-McLain EcoTec 80 Manual

Wall mount gas-fired condensing boilers - combi and heating only models
Table of Contents

Advertisement

G
-
®
ECO
Tec
AS
FIRED WATER BOILER
Contents
The ECO Tec Gas-fired water boilers . . . . . . . . . . . . . 3
Please read before proceeding . . . . . . . . . . . . . . . . 6
Boiler location . . . . . . . . . . . . . . . . . . . . . . . . . 7
Prepare boiler location . . . . . . . . . . . . . . . . . . . . . 9
Wall-mounting the boiler. . . . . . . . . . . . . . . . . . . 10
Boiler hydrostatic test . . . . . . . . . . . . . . . . . . . . 12
Gas conversions . . . . . . . . . . . . . . . . . . . . . . . 14
Gas piping - sizing gas lines . . . . . . . . . . . . . . . . 19
Venting/air piping - general . . . . . . . . . . . . . . . . 20
Vent termination requirements . . . . . . . . . . . . . . . 25
Boiler room air openings. . . . . . . . . . . . . . . . . . . 26
DIRECT VENT - Sidewall concentric . . . . . . . . . . . . 30
DIRECT VENT - Vertical concentric. . . . . . . . . . . . . 36
Install boiler water piping . . . . . . . . . . . . . . . . . . 41
Boilers only . . . . . . . . . . . . . . . . . . . . . . . . . 46
Verify the application will work: . . . . . . . . . . . . . . . . . 46
Expansion tank location. . . . . . . . . . . . . . . . . . . . . . 46
Diaphragm- or bladder-type tank: . . . . . . . . . . . . . . . . 46
Closed-type expansion tank: . . . . . . . . . . . . . . . . . . . 47
Install relief valve . . . . . . . . . . . . . . . . . . . . . . . . . 48
ZONE VALVE zoning - direct connection . . . . . . . . . . . . . 49
Expansion tank location. . . . . . . . . . . . . . . . . . . . . . 50
Diaphragm- or bladder-type tank: . . . . . . . . . . . . . . . . 50
Closed-type expansion tank . . . . . . . . . . . . . . . . . . . 50
Install relief valve . . . . . . . . . . . . . . . . . . . . . . . . . 51
System water piping methods . . . . . . . . . . . . . . . . . . 52
ZONE VALVE zoning - primary/secondary . . . . . . . . . . . . . . . 53
Circulator zoning - primary/secondary . . . . . . . . . . . . . . . . 54
Circulator zoning - Multiple temperature zones with primary/secondary .55
Gas piping . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Field wiring . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Hazard definitions
The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels
or to important information concerning the life of the product.
Indicates presence of hazards that will cause severe
personal injury, death or substantial property
damage.
Indicates presence of hazards that can cause severe
personal injury, death or substantial property
damage.
2
-
80/110/150/199
DO NOT SERVICE THE BOILER
WITHOUT AN
MAINTENANCE KIT AVAILABLE
The maintenance kit includes components that may have to be
replaced when accessing or disassembling parts of the boiler.
Failure to replace damaged components and to use only the
parts specifically intended for the boiler can result in severe
personal injury, death or substantial property damage. See
Figure 125, page 137 for part number.
Wiring diagram - schematic . . . . . . . . . . . . . . . . 66
Wiring diagram - ladder . . . . . . . . . . . . . . . . . . 68
Zoning with the ECO Tec Control. . . . . . . . . . . . . . . 70
ECO Tec control operation . . . . . . . . . . . . . . . . . . 72
Control settings menus . . . . . . . . . . . . . . . . . . . 76
EXPRESS SETUP - Example A . . . . . . . . . . . . . . . 78
EXPRESS SETUP - Example B . . . . . . . . . . . . . . . 80
EXPRESS SETUP - Example C . . . . . . . . . . . . . . . 82
HOMEOWNER NAVIGATION menus . . . . . . . . . . . . . . 86
CONTRACTOR menus . . . . . . . . . . . . . . . . . . . . . 87
BOILER SETTINGS menu . . . . . . . . . . . . . . . . . . . 88
Priority Setting screens . . . . . . . . . . . . . . . . . . . 89
System Settings . . . . . . . . . . . . . . . . . . . . . . . 91
Configure Inputs and Outputs . . . . . . . . . . . . . . . . 92
AUX Pump/Output . . . . . . . . . . . . . . . . . . . . . . 93
DIAGNOSTIC menu . . . . . . . . . . . . . . . . . . . . . . 94
SERVICE menus . . . . . . . . . . . . . . . . . . . . . . . 96
Startup - fill the system . . . . . . . . . . . . . . . . . . 97
Startup - final checks . . . . . . . . . . . . . . . . . . . 99
Annual startup . . . . . . . . . . . . . . . . . . . . . . . . 106
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . 114
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . 126
Cleaning heat exchanger flue side . . . . . . . . . . . . . 127
folds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Replacement parts . . . . . . . . . . . . . . . . . . . . . . 136
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . 148
Ratings - ECO Tec boilers . . . . . . . . . . . . . . . . . 149
Indicates presence of hazards that will or can
cause minor personal injury or property damage.
Indicates special instructions on installation,
operation or maintenance that are important
but not related to personal injury or property
damage.
B
M
OILER
ANUAL
ECO Tec
Part number 550-100-260/0520

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecotec 110Ecotec 150Ecotec 199

Table of Contents