Important Safety Information

Please read the following safety information carefully
before installing the Baseline Switch 2816-SFP/2824-SFP
Plus.
WARNING: Installation and removal of the unit must be
carried out by qualified personnel only.
If installing the Switch unit in a stack with other
units, the Switch unit must be installed below the
narrower units and above the deeper units.
The unit must be connected to an earthed
(grounded) outlet to comply with international safety
standards.
Do not connect the unit to an A.C. outlet (power
supply) without an earth (ground) connection.
The appliance coupler (the connector to the unit and
not the wall plug) must have a configuration for
mating with an EN60320/IEC320 appliance inlet.
The socket outlet must be near to the unit and easily
accessible. You can only remove power from the unit
by disconnecting the power cord from the outlet.
This unit operates under SELV (Safety Extra Low
Voltage) conditions according to IEC 60. The
I
NFORMATION
conditions are only maintained if the equipment to
which it is connected also operates under SELV
conditions.
France and Peru Only
This unit cannot be powered from IT
supplies are of IT type, this unit must be powered by
230 V (2P+T) via an isolation transformer ratio 1:1, with
the secondary connection point labelled Neutral,
connected directly to earth (ground).
Impédance à la terre
supplies. If your