PhysiGait Live
Thank you for purchasing PhysiGait Live, the easy-to-use system to accurately measure
®
spatio-temporal gait performances in record time. Physilog
5 sensors measure the
movement in the field while a dedicated mobile application computes the relevant
information to offer immediate results with in-lab precision. This manual introduces how to
use the sensors and mobile application to perform gait analysis.
PhysiGait user manual v1.3.1 Date: 29.04.2019
Copyright © 2018, All Rights Reserved - Gait Up SA. CH-1015 Switzerland
1

Advertisement

Table of Contents
loading

Summary of Contents for Gait up PhysiGait Live

  • Page 1 TVA CHE-145.136.760 User manual and Outcome parameters PhysiGait Live Thank you for purchasing PhysiGait Live, the easy-to-use system to accurately measure ® spatio-temporal gait performances in record time. Physilog 5 sensors measure the movement in the field while a dedicated mobile application computes the relevant information to offer immediate results with in-lab precision.
  • Page 2: Table Of Contents

    Clearance Analysis ....................16 Limited Warranty & Support Policy ............... 17 ® Certification claims for Physilog 5 sensors ............18 Contact information ......................19 PhysiGait user manual v1.3.1 Date: 29.04.2019 Copyright © 2018, All Rights Reserved - Gait Up SA. CH-1015 Switzerland...
  • Page 3: Physigait Live Elements

    Gait report data to the tablet. is available. PhysiGait user manual v1.3.1 Date: 29.04.2019 Copyright © 2018, All Rights Reserved - Gait Up SA. CH-1015 Switzerland...
  • Page 4: Recording With Physilog

    Signals Visualizer part of the app. For devices with small screen (such as smart phones), the sensor connection screen is available after clicking on the image of PhysiGait user manual v1.3.1 Date: 29.04.2019 Copyright © 2018, All Rights Reserved - Gait Up SA. CH-1015 Switzerland...
  • Page 5: Attachment

    Physilog®5. Attachment The PhysiGait Live is delivered with 2 rubber clips as default accessory. Elastic foot straps can be bought from the web-shop (shop.gaitup.com) if needed, for example to measure barefoot gait.
  • Page 6: Start The Recording

    “Stop”. Walk Gait Up's PhysiGait Live system can be used to measure various walking tests, the system is designed for logged gait tests of various length and protocol such as 20m gait test, 6min walk test or a figure-of-eight test. When measuring several different protocols or conditions it is recommended to do a measurement for each trial, that is: start and stop the recording for each test.
  • Page 7: Stop The Recording

    During this time do not close the application or stop the sensors via the main button. Once the entire file is sent to the mobile device, the sensors stop shining and the files are uploaded to Gait Up's server where they are analysed. Shortly after you can display the gait report.
  • Page 8 Android Application. More information and explanations about how to use these parts are available in the user manual of the companion app (RTKapp_P5_user_manual.pdf). PhysiGait user manual v1.3.1 Date: 29.04.2019 Copyright © 2018, All Rights Reserved - Gait Up SA. CH-1015 Switzerland...
  • Page 9: Gait Up Dashboard

    Write the Subject name in the field above the table to display reports for this person only. PhysiGait user manual v1.3.1 Date: 29.04.2019 Copyright © 2018, All Rights Reserved - Gait Up SA. CH-1015 Switzerland...
  • Page 10: Practical Considerations

    The correct configuration is pre-installed when you order a PhysiGait Live, so you don't need to modify the configuration of the Physilog®5. Sensor...
  • Page 11: Handling / Maintenance

    Warning: Do not use or charge the Physilog® if the sensor or its case is damaged. Contact Gait Up about what further action is needed when the case is damaged. In case the battery is damaged immediately move the device away from flammable materials and contact Gait Up's customer support.
  • Page 12: Troubleshoot

     Physilog®5 should be charged through USB connection with a computer. An external charger may be used; note that no charger is provided by Gait Up. Gait Up declines any responsibility due to charger usage.  Supply voltage should be as follows: DC, 5V. Current consumption is 100mA. All external circuits connected to the Physilog®5 should be «Safety Extra Low Voltage»...
  • Page 13 Charge the Physilog® Error 4 Contact Gait Up Error 5 Contact Gait Up Error 6 Empty the memory card *see LED indication above PhysiGait user manual v1.3.1 Date: 29.04.2019 Copyright © 2018, All Rights Reserved - Gait Up SA. CH-1015 Switzerland...
  • Page 14: Gait Parameter Overview

    Stance [%] is the portion of the cycle during which part of the foot touches the ground. Normal stance is around 60% of gait cycle duration. PhysiGait user manual v1.3.1 Date: 29.04.2019 Copyright © 2018, All Rights Reserved - Gait Up SA. CH-1015 Switzerland...
  • Page 15: Spatial Analysis

    Swing Width [m] is the maximal lateral excursion of the foot during swing phase. It is the maximum lateral distance between the forward path and the real path of the foot. PhysiGait user manual v1.3.1 Date: 29.04.2019 Copyright © 2018, All Rights Reserved - Gait Up SA. CH-1015 Switzerland...
  • Page 16: Turning Analysis

    C: Min. Toe Clearance [m] is the minimum height of the toes during swing phase. D: Max. Toe Clearance 2 [m] is the maximal height above the ground reached by the toes just before heel strike. PhysiGait user manual v1.3.1 Date: 29.04.2019 Copyright © 2018, All Rights Reserved - Gait Up SA. CH-1015 Switzerland...
  • Page 17: Limited Warranty & Support Policy

    7. Limited Warranty & Support Policy Warranty: Gait Up offers 12 months parts and labour on Physilog® starting from the date of delivery. If within one year from the date of delivery to the customer the equipment does not comply with the foregoing Limited warranty, Gait Up will at Gait Up’s option, repair, replace or refund the purchase price of the defective equipment free of...
  • Page 18: Sensors

    This device complies with FCC radiation exposure limits set forth for general population. This device must not be co-located or operating in conjunction with any other antenna or transmitter. PhysiGait user manual v1.3.1 Date: 29.04.2019 Copyright © 2018, All Rights Reserved - Gait Up SA. CH-1015 Switzerland...
  • Page 19: Certification Claims For Physilog Contact Information

    Rebekka Anker 17.12.2018 Change “client” to “subject” after renaming in 1.3.1 Rebekka Anker 29.04.2019 GaitUp app v1.8.0 Update pictures to new design PhysiGait user manual v1.3.1 Date: 29.04.2019 Copyright © 2018, All Rights Reserved - Gait Up SA. CH-1015 Switzerland...