Integrated Steppers
If you are a new user of LabVIEW or are unfamiliar with LabVIEW, refer to
Note
the Getting Started with LabVIEW manual for information about LabVIEW and
LabVIEW terminology.
This document explains how to install and configure the NI ISM-7411/7412/7413 integrated
steppers.
Contents
What You Need to Get Started ................................................................................................. 1
Hardware .......................................................................................................................... 1
Software............................................................................................................................ 2
Related Documentation .................................................................................................... 2
Hardware Installation and Configuration ................................................................................. 3
Step 1: Connect the NI PS-12/13 Power Supply .............................................................. 3
Step 2: Connect the Integrated Stepper to the Network ................................................... 4
Step 3: Verify the Connections......................................................................................... 8
Using the ISM with SoftMotion ............................................................................................... 8
Running the Example ....................................................................................................... 8
Understanding the Example.............................................................................................. 9
Worldwide Support and Services ............................................................................................. 10

What You Need to Get Started

You need the following items to get started.

Hardware

12 VDC to 70 VDC power supply. NI PS-12 (NI part number 748906-01) or
NI PS-13 (NI part number 748907-01) recommended.
Tool for inserting wires into a screw terminal connector
A PC running Microsoft Windows 8.1/8/7/Vista/XP SP3, with an available Ethernet port
A CAT5 Ethernet cable (not included)
NI ISM 7411/7412/7413 integrated stepper

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ISM-7411 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for National Instruments ISM-7411

  • Page 1: Table Of Contents

    If you are a new user of LabVIEW or are unfamiliar with LabVIEW, refer to Note the Getting Started with LabVIEW manual for information about LabVIEW and LabVIEW terminology. This document explains how to install and configure the NI ISM-7411/7412/7413 integrated steppers. Contents What You Need to Get Started ....................1 Hardware ..........................
  • Page 2: Software

    LabVIEW, and reference information about LabVIEW VIs, functions, palettes, menus, tools, properties, methods, events, dialog boxes, and so on. The LabVIEW Help also lists the LabVIEW documentation resources available from National Instruments. Access the LabVIEW Help by selecting Help»LabVIEW Help. •...
  • Page 3: Hardware Installation And Configuration

    Hardware Installation and Configuration This section covers the hardware setup for the NI ISM-7411/7412/7413 integrated stepper. Step 1: Connect the NI PS-12/13 Power Supply Do not plug in or turn on the power supply until after you complete all of the Note following steps.
  • Page 4: Step 2: Connect The Integrated Stepper To The Network

    The IP address automatically assigned by the DHCP server may be dynamic or static depending on how the administrator has configured DHCP. The DHCP setting is reserved for advanced users. 4 | ni.com | Getting Started NI ISM-7411/7412/7413 Integrated Steppers...
  • Page 5 Right-click your network interface card (NIC) and select Properties. —Scroll down and select (TCP/IPv4), then click Properties. Windows 8.1/8/7/Vista —Scroll down and select Internet Properties (TCP/IP), then click Windows XP Properties. Getting Started NI ISM-7411/7412/7413 Integrated Steppers | © National Instruments | 5...
  • Page 6 Discovery will look for additional devices on you network. Once you have told Drive Discovery which device is yours, it automatically enters the device IP address in the IP address text box so that you are ready to communicate. 6 | ni.com | Getting Started NI ISM-7411/7412/7413 Integrated Steppers...
  • Page 7 —Open Control Panel. From the icon view, open Network Windows 8.1/8/7/Vista and Sharing Center, then click Change Adapter Settings. —Right-click My Network Places and select Properties. Windows XP Getting Started NI ISM-7411/7412/7413 Integrated Steppers | © National Instruments | 7...
  • Page 8: Step 3: Verify The Connections

    Absolute, Relative, and Velocity. For information about the different kinds of moves, refer to the SoftMotion Help. • Axis— Enter the IP address of the integrated stepper. For example, a device using the universal recovery address would be entered as niss:\\10.10.10.10 8 | ni.com | Getting Started NI ISM-7411/7412/7413 Integrated Steppers...
  • Page 9: Understanding The Example

    When the move is started, all of the configured parameters are written with a property node. The position feedback is read with an invoke node and displayed. Figure 5. Applying the Move Parameters Getting Started NI ISM-7411/7412/7413 Integrated Steppers | © National Instruments | 9...
  • Page 10: Worldwide Support And Services

    NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS.