GHARiENi Lina Select Alu Instruction Manual

GHARiENi Lina Select Alu Instruction Manual

Treatment tables
Hide thumbs Also See for Lina Select Alu:
Table of Contents

Advertisement

Treatment Tables of the
Lina Select Wood
Fig. similar: colour, upholstery and equipment may vary depending on model.
➢ Phone:
➢ Fax:
➢ Customer service hotline:
➢ E-mail:
➢ Web:
Empty field for entering the
The serial number of the treatment table is on the
rating plate (s. chapter 7. R
Instruction Manual
Lina Select Alu
Gharieni Group GmbH
Am Schürmannshütt 24
D - 47441 Moers
SERIAL NUMBER
).
ATING PLATE
Lina Select line
Lina Select Static
+49 (0)2841/88300-0
+49 (0)2841/88300-999
+49 (0)2841/88300-40
service@gharieni.com
www.gharieni.com
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Lina Select Alu and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GHARiENi Lina Select Alu

  • Page 1 Instruction Manual Lina Select line Treatment Tables of the Lina Select Alu Lina Select Wood Lina Select Static Fig. similar: colour, upholstery and equipment may vary depending on model. Gharieni Group GmbH Am Schürmannshütt 24 D - 47441 Moers ➢ Phone: +49 (0)2841/88300-0 ➢...
  • Page 2: Table Of Contents

    BBREVIATIONS : Lina Select Alu In the instruction manual also REATMENT TABLE : Lina Select Wood → referred to generally as Lina REATMENT TABLE : Lina Select Static Select. REATMENT TABLE REFACE Dear Customer, we would like to thank you for purchasing this quality-product as well as for your confidence.
  • Page 3 10.1.1 Alu Design MCP of the Lina Select Alu ............26 10.1.2 MCP of the Lina Select Wood / Static............29 10.1.3 Lina Select Alu: Locking function of the Alu Design MCP ...... 31 10.1.4 Lina Select Wood / Static: Locking function of the MCP ......32 10.1.5 Lina Select Alu: memory function of the Alu Design MCP .....
  • Page 4 10.2 Adjustment of the work height ................36 10.3 Adjustment of the backrest ..................36 10.4 Adjustment of the seat inclination ................ 36 10.5 Adjustment of the leg section ................37 10.5.1 Footrest ....................... 38 11. Foot control panel (optional equipment) ..............38 12.
  • Page 5: Safety Information

    Copies of this instruction manual are available upon request. ➢ The Gharieni Group GmbH shall not be held responsible for any damages, direct or indirect, caused to people, animals or objects resulting from negligence or non- compliance with the instructions contained herein.
  • Page 6: Abbreviations

     Store this manual in a safe place so you can use it whenever it is needed. Strictly observe the instructions to avoid damage to persons and property. 1.1 Abbreviations : Lina Select Alu ➢ In the instruction manual also REATMENT TABLE : Lina Select Wood...
  • Page 7 4. Do not modify the plug provided with the Lina Select, if it will not fit the outlet, have a proper outlet installed by a qualified electrician (not covered by the guarantee). 5. Do not connect the Lina Select to the mains if the treatment table itself or the power cable or the plug are visibly damaged.
  • Page 8 3. Check all cables regularly and contact our Customer Service Department when any cable is in improper condition. RISK OF ELECTRIC SHOCK! 4. The Lina Select must not stand on the power cord. Ensure that the cord is not damaged when moving the treatment table. Do not step on the cord.
  • Page 9 ELECTRIC SHOCK! RISK OF DAMAGE! 26. Any repairs and maintenance work must be carried out by qualified professionals authorized by the Gharieni Group GmbH only! RISK OF ELECTRIC SHOCK! RISK OF FIRE! 27. Do not use a steam cleaner for cleaning. RISK OF ELECTRIC SHOCK! 28.
  • Page 10 31. Always ensure that no parts of the body or items are between the parts of the Lina Select while adjusting the lying position. RISK OF CRUSHING! 32. Do not use the supporting structure as a foot rest. RISK OF CRUSHING! 33.
  • Page 11: Intended Use

    Read the instructions very carefully and only operate the treatment table in its intended use as described to protect you and your customers from danger: ❖ The Gharieni Lina Select is not a medical device relevant to the medical products law (German: MPG).
  • Page 12: Preliminary Remarks

    4. Preliminary remarks ❖ The Gharieni treatment table Lina Select is subject to the highest safety and quality standards. ❖ Before initial operation, please check that all components are present and that they are not visible damaged. ❖ The dedicated safety socket must be grounded properly and must meet the proper voltage.
  • Page 13: Transport, Space Requirement And Installation

    ➢ The headrest is in the same cardboard. The headrest has to be installed (see chapter 9.4.1 H EADREST 6. Transport, space requirement and installation 6.1 Transport Always consider the dimensions of the Lina Select. A transport of the Lina Select can be severely affected to some extent due to unfavourable environment conditions.
  • Page 14: Space Requirement

    6.2 Space requirement ❖ Before installation, ensure that there is sufficient free space for the Lina Select relevant to its total length. ➢ Min. free space required for the Lina Select (standard upholstery): Length = min. 202.00 cm * Width = min. 80.00 cm. ➢...
  • Page 15: Upholstery And Base Versions

    If you wish to contact the Gharieni customer service regarding your treatment table, we recommend taking a photo of the rating plate previously (e.g. using a mobile phone or a digital camera). This makes it easier for you to identify the information of the ...
  • Page 16: Soft Upholstery (Polyurethane)

    ❖ The treatment tables of the Lina Select line are available in three base versions. 8.2.1 Lina Select Alu ❖ The base of the Lina Select Alu is made of a solid pedestal which is clad with aluminium. The pedestal provides a decorative eye-catcher because of the lateral...
  • Page 17: Lina Select Wood

    Fig. similar: colour and upholstery may vary depending on model. CLAD WITH ALUMINIUM INCL APPLICATIONS 8.2.2 Lina Select Wood ❖ The base of the Lina Select Wood consists of a solid and elegant pedestal with wood decor. Fig. similar: colour and upholstery may vary depending on model. SOLID PEDESTAL WITH WOOD DECOR...
  • Page 18: Lina Select Static

    Lina Select. RISK OF TIPPING! RISK OF DISINTEGRATION! RISK OF INJURY! 9.1 Characteristics ❖ The Gharieni Lina Select is a treatment table which is equipped with four actuators; s. chapter 9.2 N . When operating these UMBER OF ACTUATORS actuators, you can easily adjust the desired positions electrically using the manual control panel.
  • Page 19: Number Of Actuators

    9.2 Number of actuators ❖ The treatment tables of the Gharieni Lina Select series are equipped with four actuators. When operating these actuators, you can easily adjust the desired positions electrically using the manual control panel.
  • Page 20: Before Initial Use

    ➢ The Alu Design manual control panel (MCP) of the Lina Select Alu is equipped with four preprogrammed and four freely-selectable memory positions. ➢ The manual control panel (MCP) of the Lina Select Wood / Lina Select Static is equipped with eight freely-selectable memory positions.
  • Page 21: Headrest

    ACKREST ➢ the backrest is electrically-adjustable for all base versions. ➢ mechanical A ®. IRBACK ➢ see also chapter 9.4.3 B ACKREST ➢ see also chapter 10.3 A DJUSTMENT OF THE BACKREST EADREST ➢ manually-extendable; removable. ➢ see also chapter 9.4.1 H EADREST RMRESTS ➢...
  • Page 22: Armrests

    Fig. similar: colour and upholstery may vary depending on model.  To provide an opening for the nose (in massage position), extract the headrest by approx. 10 cm. Our popular "D ” is optional available for our treatment NECK REST ENTALAX tables.
  • Page 23: Backrest

    NOTICE! Do not lean, stand, kneel or sit on the armrests; otherwise you can damage the armrests permanently! RISK OF DAMAGE! NOTICE! The maximum loading capacity of the armrests is 25.00 kg. RISK OF DAMAGE! 9.4.3 Backrest ❖ The backrest (5) of the Lina Select is electrically-adjustable; s. fig. in chapter 9.4 and s.
  • Page 24: Leg Section

    When the customer is placed in prone position, do not use the A ®. IRBACK ➢ You can deflate the A ® using the black button of the grey hand pump. IRBACK NOTICE! Do not pump the air cushions too much; otherwise the air cushions can be possible damaged due to the own weight of the customer.
  • Page 25: Adjustments Of The Lina Select

    10. Adjustments of the Lina Select ❖ The electrical adjustments of the Lina Select are carried out using a manual control panel (MCP). ❖ The electrical adjustments can also be carried out using an optionally available foot control panel; s. chapter 11. F OOT CONTROL PANEL OPTIONAL EQUIPMENT...
  • Page 26: Alu Design Mcp Of The Lina Select Alu

    10.1.1 Alu Design MCP of the Lina Select Alu Alu Design MCP: Lina Select Alu only! The Alu Design MCP of the Lina Select Alu is equipped with four pre- programmed and four freely-selectable memory positions. ❖ You can control each of the 4 actuators individually by simply pressing the relevant push buttons (level 1, standard mode, white lettering).
  • Page 27 Fig. similar: modifications are possible. ➢ Push buttons for the adjustment of the (white WORK HEIGHT lettering / arrows). A / A1 ➢ Push buttons for the retrieval of the preprogrammed MEMORY « » and « » (grey lettering); s. POSITIONS HEAD AREA FOOT AREA...
  • Page 28 (level 2 button / grey lettering) TART BUTTON ➢ The resets the Lina Select to the basic position or START BUTTON has no function ➢ The basic position is not changeable. ➢ Available in level 2 only. (level 1 button / black lettering) OCKING BUTTON ➢...
  • Page 29: Mcp Of The Lina Select Wood / Static

    10.1.2 MCP of the Lina Select Wood / Static Lina Select Wood and Lina Select Static only! ❖ You can control each of the 4 actuators individually by simply pressing the relevant push buttons (level 1, standard mode, black lettering). ❖...
  • Page 30 Fig. similar: modifications are possible. ➢ Push buttons for the adjustment of the (black WORK HEIGHT lettering / arrows). A / A1 ➢ Push buttons for the saving and retrieval of the MEMORY M 1 and M 2 (grey lettering). POSITIONS ➢...
  • Page 31: Lina Select Alu: Locking Function Of The Alu Design Mcp

    For safety reasons, the Lina Select moves only while pressing a button  of the MCP. When you stop pressing, all moving-operation will stop immediately. 10.1.3 Lina Select Alu: Locking function of the Alu Design MCP ❖ The Lina Select Alu is equipped with a of the Alu Design LOCKING FUNCTION MCP to protect the treatment table from unauthorized access.
  • Page 32: Lina Select Wood / Static: Locking Function Of The Mcp

    MCP are LOCKING FUNCTION released. NOTICE! To prevent unauthorized use of the Lina Select Alu, always activate the locking function of the MCP when leaving the treatment room. 10.1.4 Lina Select Wood / Static: Locking function of the MCP ❖...
  • Page 33: Lina Select Alu: Memory Function Of The Alu Design Mcp

    (MCP) when leaving the treatment room. 10.1.5 Lina Select Alu: memory function of the Alu Design MCP ❖ The MCP of the Lina Select Alu has four preprogrammed memory positions (memory function on level 2: HEAD AREA...
  • Page 34 3. Press and hold the relevant (hotkey: head MEMORY BUTTON area / foot area / seat area or massage) until the desired treatment position has been reached. ELECT OW TO SAVE A FREELY SELECTABLE MEMORY POSITION 1. Set the desired position as normal. 2.
  • Page 35: Lina Select Wood / Static: Memory Function Of The Mcp

    10.1.6 Lina Select Wood / Static: memory function of the MCP ❖ The MCP of the Lina Select Wood / Static has eight freely-selectable memory positions (memory function on level 2: M 1 / M 2 / M 3 / M 4 / M 5 / M 6 / M 7 / M 8).
  • Page 36: Adjustment Of The Work Height

    10.2 Adjustment of the work height ❖ For the adjustment of the press the pair of push buttons « A / A1 » WORK HEIGHT of the relevant MCP; s. fig. in chapter 10.1 M (MCPs) et ANUAL CONTROL PANELS seq.
  • Page 37: Adjustment Of The Leg Section

    ❖ The direction of movement (up or down) is indicated by the arrow-symbols on the respective MCP. Fig. similar: colour, upholstery and design may vary depending on model. 10.5 Adjustment of the leg section ❖ The inclination of the of the Lina Select can also be adjusted easily LEG SECTION using the MCP.
  • Page 38: Footrest

    10.5.1 Footrest ❖ As well as the you can pull out the (9) of the HEADREST FOOTREST LEG SECTION (8) to increase its length. ❖ Furthermore, you can remove the (9), so you can work on the heel FOOTREST area (pedicure). This setting is also suitable when you want to carry out massages without using additional tools (lowered foot position).
  • Page 39 Fig. similar: modifications are possible. ELECTION OF A FUNCTION R 1 / RIGHT FOOT SWITCH UNIT ➢ serves as when you have selected the memory SAVE BUTTON function. R 2 / RIGHT FOOT SWITCH UNIT ➢ selects the (height, backrest, seat inclination, leg ACTUATORS section) or the (lower diode) step by...
  • Page 40 OW TO ADJUST THE ACTUATORS 1. Select the desired actuator (height, backrest, seat inclination, leg section) using the push button R 2 of the right foot switch-unit. Press the push button R 2 repeatedly until the relevant diode on the connector goes on (s. above; fig. 2). 2.
  • Page 41: Heating System Smart Thermo 3 (Optional Equipment)

    OW TO ACTIVATE THE LOCKING FUNCTION 1. Press and hold the push button R 2 until an acoustic signal sounds. 2. Immediately after this acoustic signal (within 3 seconds) press and hold the push button L 1 until another acoustic signal sounds. 3.
  • Page 42 The heating parameters of the Smart Thermo can be changed if desired (s. chapter 12.1 O ): you can set both the heating/power level and the heating time PERATION individually using the control panel of the Smart Thermo (s. fig. in chapter 12.1). Check the current temperature before using the Lina Select.
  • Page 43: Operation

    12.1 Operation ❖ You can operate the heating system using the 4 buttons (s. fig. below: CONTROL PANEL OF THE HEATING SYSTEM MART HERMO ❖ The setting of the heating power and the time selection is indicated by a 10-level LED bar-diagram.
  • Page 44 2 blue LEDs 2 green LEDs 2 yellow LEDs 2 orange LEDs 2 red LEDs UTTON ❖ Press this button to switch on the Smart Thermo. 1. When the Smart Thermo is switched on, it starts heating at the maximum heating / power level for 5 minutes (level 5: the 2 red LEDs (E) are illuminated).
  • Page 45 IVE HEATING POWER LEVELS ARE AVAILABLE Level 1 Minimum power = low temperature Level 2 Heating / power level between minimum and medium power Level 3 Medium power = medium temperature Level 4 Heating / power level between medium and maximum power Level 5 Maximum power = high temperature The selected heating / power level will be displayed on the LEDs above the...
  • Page 46 IME SELECTION BUTTON ❖ Press this button to set the required heating time of the Smart Thermo. ➢ Ten time settings (in 10-minutes intervals) are available which are displayed on the LEDs (10 LEDs). ➢ You can select a heating time from 10 minutes up to 100 minutes by pressing one or several times.
  • Page 47: Vibro Wellness 10 (Optional Equipment)

    8. After the set time has elapsed the Smart Thermo switches off automatically. ➢ If you wish to quit the heating time earlier, press the button to switch off the Smart Thermo. ❖ When programming the Smart Thermo it does not matter whether you wish to set the time at first and the temperature secondly or vice versa.
  • Page 48: Manual Control Panel

    WARNING! The cables of the models incl. the Vibro Wellness 10 function are between the upholstery and the underframe (depending on model). Removing of the upholstery must be carried out by authorized professionals only! 13.1 Manual control panel The 10 motors of the V 10 function are installed in different IBRO ELLNESS...
  • Page 49: Operation

    ELLNESS MASSAGE BUTTON AVE BUTTON NTENSITY BUTTONS SHOULDER AREA BACK AREA NTENSITY BUTTONS FUSELAGE AREA BACK AREA NTENSITY BUTTONS PELVIC AREA BACK AREA NTENSITY BUTTONS LEG AREA NTENSITY BUTTONS CALF AREA FOOT AREA Button to change the of the SPEED PULSE MASSAGE PROGRAMME (three levels).
  • Page 50 ULSE MASSAGE BUTTON ❖ Start this massage with the first of the three pulse-massage programmes. ELLNESS MASSAGE BUTTON ❖ Start this massage with the first of the three wellness-massage programmes. (5-9) NTENSITY BUTTONS ❖ Pressing one of these buttons sets the relevant massage motor to intensity level Please note: Doing so will overwrite a previously-set individual setting (s.
  • Page 51 (3): ULSE MASSAGE ➢ Press the (3) to start the massage with the first of the PULSE MASSAGE BUTTON three programmes. ➢ Press the (3) a second time to start the second PULSE MASSAGE BUTTON programme. ➢ Press the (3) a third time to start the third programme. PULSE MASSAGE BUTTON ➢...
  • Page 52: Initialisation Of The Software / Reset

    14. Initialisation of the software / Reset 14.1 Initialisation of the software ❖ If a previously-saved position is no longer properly set, you may have to initialise the software of the Lina Select. To correct the differences of position, you have to carry out the following steps: NITIALISATION The respective MCP must be in...
  • Page 53: Reset

    MCP: MCP: Lina Select Alu Lina Select Wood / Static The adjustment (initialisation) must be carried out manually, i.e. each actuator has to be run individually. When the final positions are set, please keep pressing the push  buttons for additional 2 to 3 seconds.
  • Page 54: Cleaning And Maintenance

    15. Cleaning and maintenance WARNING! Disconnect the Lina Select from the mains (unplug) before cleaning and maintenance. RISK OF ELECTRIC SHOCK! RISK OF FIRE! WARNING! Remove possible dust accumulation at the power plug, at the safety power socket and at all plug connectors regularly. RISK OF FIRE! WARNING! Ensure that water or other liquids cannot get into the housing and the fittings of the Lina Select or into the MCPs.
  • Page 55: Cleaning And Care Of The Surface Of The Upholstery

    POLYURETHANE 15.1.1 Cleaning and care of the artificial leather ❖ Clean and care the artificial leather using a special detergent for artificial leather only; optional available from Gharieni: s. chapter 17. O PTIONALLY AVAILABLE ACCESSORIES 15.1.2 Cleaning and care of the polyurethane material (PU) ❖...
  • Page 56: Malfunctions (Possible Causes And Troubleshooting)

    16. Malfunctions (possible causes and troubleshooting) ALFUNCTION OSSIBLE CAUSE ROUBLESHOOTING LL MOTORS DO NOT WORK 1. No connection to the mains. 1. Check the connection status. 2. The power supply cable is damaged. 2. Power supply cable must be replaced (please contact customer...
  • Page 57: Repair

    1. When contacting the customer service, the information about the serial number is absolutely necessary. 2. Repairs and modifications must be carried out by Gharieni Group GmbH or a person authorized by Gharieni Group GmbH. 3. The electrical installation of the room the treatment table is installed in must meet the current legal regulations at the site where the treatment table is operated.
  • Page 58: Optionally Available Accessories

    17. Optionally available accessories  For detailed information regarding the optionally available accessories (s. below) please contact the Gharieni customer service. We will be glad to advise you! 17.1 Castor set ❖ A with brakes for a treatment table of the Lina Select line is optional CASTOR SET available for an additional charge.
  • Page 59: Upholstery Care: MikrozidĀ® Sensitive

    NOTICE! Use the cleaner for artificial leather only. NOTICE! Do not use the cleaner for the PU upholstery! 17.3 Upholstery care: mikrozid® sensitive ❖ For the gentle and thorough care of the upholstery of our treatment tables we recommend mikrozid® sensitive. ❖...
  • Page 60: Neck Rest "Dentalax

    ECK REST ENTALAX  For detailed information regarding the suitable version for your treatment table please contact the Gharieni customer service. We will be glad to advise you! 17.6 Protective covers for treatment tables ❖ C for our treatment tables are optional available for an OVERS MADE OF TERRY additional charge.
  • Page 61: Conditions Of Transport, Storage And Operation

    Fig. similar: fig serves as an example only!  For detailed information regarding the right size and suitable version of the covers as well as the compatibility with your treatment table please contact the Gharieni customer service. We will be glad to advise you! 18.
  • Page 62: Technical Data

    19. Technical data ENERAL TECHNICAL DATA Total length approx. 202.00 cm Width (max.) approx. 80.00 cm Range of height adjustments incl. adjustable feet approx. 54.00 cm - 96.00 cm Range of height adjustments incl. adjustable feet approx. 59.00 cm - 101.00 cm (soft upholstery) Range of height adjustments incl.
  • Page 63 EATING SYSTEM MART HERMO OPTIONAL EQUIPMENT Power supply 230 V AC / 48 - 60 Hz Power consumption ca. 120 W (VA) max. Protection 630 mA-T Transformer output voltage 12 V AC / ca. 9A max. ❖ Technical modifications reserved. 10 ( IBRO ELLNESS...
  • Page 64: Waste Management

    9. If suitable containers are not available at your residential area, dispose of these materials at a suitable municipal collection point for waste-recycling. 10. Receive more detailed information from your retailer, municipal facilities or: Gharieni Group GmbH ➢ Phone: +49 (0)2841/88300-0 ➢...
  • Page 65: Guarantee Provisions

    21.1 Guarantee period The following guarantee provisions apply to new goods worldwide: The Gharieni Group GmbH offers for all treatment tables of the Lina Select series → a 10-year guarantee for their metal frames, → a 5-year guarantee for their actuators and →...
  • Page 66: Ec-Declaration Of Conformity

    22. EC-Declaration Of Conformity EC DECLARATION OF CONFIRMITY Hereby, we Gharieni Group GmbH Gutenbergstr. 40 D-47443 Moers declare that the design and construction of the appliance listed below complies with the relevant essential health and safety requirements of the EU,...
  • Page 67: Status Of Edition

    RESERVED. ITS REPRODUCTION OR TRANSMISSION TO THIRD PARTIES IS FORBIDDEN WITHOUT THE AUTHORISATION OF THE OWNING COMPANY. THE POWER TO PROTECT ITS RIGHTS IS RESERVED AND OFFENDERS SHALL BE PROSECUTED. Gharieni Group GmbH Am Schürmannshütt 24 D - 47441 Moers...