Page 1
➢ Fax: +49 (0)2841/88300-999 ➢ Customer service hotline: +49 (0)2841/88300-40 ➢ E-mail: service@gharieni.com www.gharieni.com ➢ Web: Empty field for entering the SERIAL NUMBER The serial number of the MLK Physio is on the rating plate (s. chapter 7. R ATING PLATE...
Reading the complete IM is essential for its proper and confident use and will help you to operate the MLK Physio to your entire satisfaction. Our MLK Physio is very robust and has a long operating life if it is operated properly.
Page 3
8. Upholstery.......................... 14 9. Operation ........................... 14 9.1 Characteristics ......................15 9.2 Numbers of actuators ....................15 9.3 Before initial use ......................16 9.4 View ..........................16 10. Pneumatic adjustments ....................17 10.1 Gas pressure springs ....................17 10.2 Adjustment of the headrest ..................18 10.3 Adjustment of the armrests ..................
Copies of this instruction manual are available upon request. ➢ The Gharieni Group GmbH shall not be held responsible for any damages, direct or indirect, caused to people, animals or objects resulting from negligence or non- compliance with the instructions contained herein.
3. The technical data of your energy supplier must meet the data on the model plate of the MLK Physio. 4. Do not modify the plug provided with the MLK Physio, if it will not fit the outlet, have a proper outlet installed by a qualified electrician (not...
Page 6
14. Never touch power plugs, power switches or other electrical components with wet or damp hands. RISK OF ELECTRIC SHOCK! 15. Do not place or store the MLK Physio close to a bath, a shower or a washbasin. There is danger that the MLK Physio may come into contact with splashed water.
Page 7
Do not use attachments / accessories not recommended by the manufacturer. 17. Never operate the MLK Physio if it has a damaged cord or plug, if it is not working properly, if it has been damaged or if it has become wet.
Page 8
22. Do not allow any unauthorized person to operate the MLK Physio! 23. Use the MLK Physio only on a level surface. 24. Do not place any objects or liquids on the MLK Physio. The treatment table as well as the material can be damaged thereby.
Page 9
RISK OF INJURY! CHOKING HAZARD! 37. Always keep children and pets away from the MLK Physio. 38. Children must not play with the MLK Physio or its single components. 39. The MLK Physio is not intended to be operated by persons with...
Read the instructions very carefully and only operate the treatment table in its intended use as described to protect you and your customers from danger: ❖ The Gharieni treatment table MLK Physio is not a medical device relevant to the medical products law (German: MPG).
➢ Open the top of the packaging carefully. Do not use any sharp-edged items which can damage the upholstery. ➢ Do not lift the MLK Physio but remove the top packaging first. Then you can lift and remove the outer packaging.
6.3 Assembly ❖ The MLK Physio is easy to install and can be adapted to all human body measurements. You can adjust the desired positions electrically in a very short period of time and then focus entirely on your customer.
❖ The rating plate is usually on the casing of the parallelogram (mechanism for the height adjustment) of the MLK Physio (s. fig. below / see also fig. in chapter 9.4 ❖ Do not make the rating plate illegible! Do not remove the rating plate! Noncompliance will expire the guarantee! Fig.
So you have the serial number always at hand. 8. Upholstery ❖ The MLK Physio is equipped with a two-part lying surface (s. fig. below). ❖ The MLK Physio is equipped with a comfortable and high-quality upholstery (s. fig. below).
9.1 Characteristics ❖ The MLK Physio is a versatile treatment table. You can use it especially for physiotherapeutic treatments but also for various other treatments (massages, etc.) in dry rooms. ❖ The MLK Physio is equipped with a high-quality comfort padding made of artificial leather.
9.3 Before initial use ➢ Before initial operation, please check that all components are present (s. chapter 3. S ) and that they are not visibly damaged. COPE OF DELIVERY ➢ The dedicated safety socket must be grounded properly and must meet the proper voltage (230 V AC).
(instructions are not depending on the adjustment of the lying surface). Failure to do so can cause permanent damage to the construction of the MLK Physio. RISK OF TIPPING! RISK OF DISINTEGRATION! RISK OF INJURY! ❖ The headrest is freely and manually adjustable.
PRESSURE SPRINGS ❖ Use the lever of the relevant side and press lightly to adjust the armrests freely. ❖ Thus, the MLK Physio is the optimal solution for back massages (s. fig. below). Fig. similar: colour may vary depending on model.
10. P et seq. NEUMATIC ADJUSTMENTS ❖ The electrical adjustments of the MLK Physio are carried out using the manual control panel (MCP); s. chapter 11.1 M (MCP) et seq. ANUAL CONTROL PANEL ❖...
❖ The direction of movement (up or down) is indicated by the arrow-symbols on the MCP. ❖ The horizontal of the MLK Physio is fully adjustable from approx. WORK HEIGHT 61.00 cm up to approx. 91.00 cm (if the adjustable feet are retracted).
➢ approx. 61.00 cm / lying surface in horizontal position 11.3 Adjustment of the two-part lying surface ❖ The MLK Physio is equipped with an electrically adjustable two-part lying surface (upper lying surface / lower lying surface); example for an adjustment of the lying surface: s.
NOTICE! Never rest, stand or kneel on any part of the lying surface of the MLK Physio. Do not exert strong physical forces on the lying surface; otherwise you can damage the upholstery permanently. RISK OF DAMAGE! 12. Foot control panel (optional equipment) ❖...
Smart Thermo (s. fig. in chapter 13.1). Check the current temperature before using the MLK Physio. Disconnect the MLK Physio from the mains when it is not used for a longer period of time, e.g. during the night.
Thermo function by pressing the OFF-button on the control panel to avoid heat accumulation. 4. Disconnect the MLK Physio from the mains when it is not used for a longer period of time, e.g. during the night. WARNING! Persons suffering from acute pain, venous disorders, low...
Page 26
ONTROL PANEL OF THE HEATING SYSTEM MART HERMO : -ON- UTTON : -OFF- UTTON EMPERATURE SELECTION BUTTON IME SELECTION BUTTON 2 blue LEDs 2 green LEDs 2 yellow LEDs 2 orange LEDs 2 red LEDs...
Page 27
UTTON ❖ Press this button to switch on the Smart Thermo. 1. When the Smart Thermo is switched on, it starts heating at the maximum heating / power level for 5 minutes (level 5: the 2 red LEDs (E) are illuminated). 2.
Page 28
The selected heating / power level will be displayed on the LEDs above the operating buttons: Level 1 blue LEDs (A) Press button one time Level 2 green LEDs (B) Press button two times Level 3 yellow LEDs (C) Press button three times Level 4 orange LEDs (D)
Page 29
XAMPLE You wish to set a medium heating / power level (level 3) of 30 minutes. Please proceed as follows: 1. Switch on the Smart Thermo by pressing the button -ON- 2. Then select the . Press this button TEMPERATURE SELECTION BUTTON repeatedly until the two yellow LEDs (C) are illuminated (s.
❖ Do not wear any arm and finger decoration such as rings or bracelets while carrying out any cleaning or maintenance operations. Otherwise, you can scratch and damage the upholstery and / or the material of the base of the MLK Physio unintentionally.
14.1 Cleaning and care of the surface of the upholstery ❖ The upholstery of the MLK Physio is equipped with a surface made of ARTIFICIAL LEATHER Clean and care the artificial leather using a special detergent for artificial leather only optional available at Gharieni;...
2. Repairs and modifications must be carried out by Gharieni Group GmbH or a person authorized by Gharieni Group GmbH. 3. The electrical installation of the room the MLK Physio is installed in must meet the current legal regulations at the site where the MLK Physio is operated.
16. Optionally available accessories For detailed information regarding the optionally available accessories (s. below) please contact the Gharieni customer service. We will be glad to advise you! 16.1 Castor set ❖ A...
❖ You can order the relevant cover when purchasing the treatment table. For detailed information regarding the right size and suitable version of the covers as well as the compatibility with your treatment table please contact the Gharieni customer service. We will be glad to advise you!
17.1 Transport ❖ Carry the MLK Physio by its base / supporting structure during transport only. ❖ Never carry the MLK Physio by its lying / sitting surface or its armrests during transport; otherwise you can damage the MLK Physio seriously.
18. Technical data ENERAL TECHNICAL DATA Total length 200.00 cm Length: headrest 45.00 cm Length: upper lying surface 50.00 cm Length: lower lying surface 105.00 cm Total weight (without options) approx. 85.00 kg Width 70.00 cm Range of height adjustments incl. adjustable feet approx.
CHOKING HAZARD! RISK OF INJURY! 2. Do not dispose of the MLK Physio together with your domestic waste. Old and unused treatment tables must be sent for disposal to the responsible recycling centre for electric appliances.
20.1 Guarantee period The following guarantee provisions apply to new goods worldwide: The Gharieni Group GmbH offers for all treatment tables of the MLK Physio series → a 10-year guarantee for their metal frames, → a 5-year guarantee for their actuators and →...
21. EC-Declaration Of Conformity EC DECLARATION OF CONFIRMITY Hereby, we Gharieni Group GmbH Gutenbergstr. 40 D-47443 Moers declare that the design and construction of the appliance listed below complies with the relevant essential health and safety requirements of the EU,...
RESERVED. ITS REPRODUCTION OR TRANSMISSION TO THIRD PARTIES IS FORBIDDEN WITHOUT THE AUTHORISATION OF THE OWNING COMPANY. THE POWER TO PROTECT ITS RIGHTS IS RESERVED AND OFFENDERS SHALL BE PROSECUTED. Gharieni Group GmbH Am Schürmannshütt 24 D - 47441 Moers...
Need help?
Do you have a question about the MLK Physio and is the answer not in the manual?
Questions and answers