Download Print this page

Advertisement

Quick Links

Installation and Service Instructions
Domestic:
Canada:
MADE
in the
USA
• In the United States, installation must conform with local codes
or in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1-latest edition available from American
National Standard Institute. Further reference should be made to
the recommendation of your fuel supplier.
• In Canada, installation must conform with local codes or in the
absence of local codes, with Installation Codes for Gas Burning
Appliances and Equipment, CGA Standard CAN/CGA 1-B-149.1
or 2. Further reference should be made to the recommendation
of your fuel supplier.
WARNING: Additions, changes, conversions and
service must be performed by an authorized Midco
representative, service agency or the fuel supplier. Use only
MIDCO specifi ed and approved parts.
• INSTALLER: Inform and demonstrate to the user the correct
operation and maintenance of the gas utilization equipment.
Inform the user of the hazards of storing fl ammable liquids and
vapors in the vicinity of this gas utilization equipment and remove
such hazards. Affi x this manual and associated literature to the
burner.
CODE
COMPLIANCE
RESPONSIBILITY OF THE INSTALLER.
• USER: Retain this manual for future reference. If other than
routine service or maintenance as described in this manual
and associated literature is required, contact a qualifi ed service
agency. DO NOT ATTEMPT REPAIRS. An inadvertent service
error could result in a dangerous condition.
FOR SERVICE CONTACT
Name:
____________________________________________
Address: ____________________________________________
____________________________________________
Phone:
____________________________________________
Date of Installation: ___________________________________
AVOID ERROR IN PARTS SELECTION. When ordering use complete
MIDCO Part Number and Description. Furnish Burner Model Number, Bill of
Material Number and Serial Number (if available) from the specifi cation plate
found on the product.
IMPORTANT: Availability of parts as well as specifi cations are subject to
change without notice. Please consult factory for item availability.
®
Midco
International Inc.
4140 West Victoria Street
Chicago, Illinois 60646
toll free 866.705.0514
tel
773.604.8700
fax
866.580.8700
web
www.midcointernational.com
e-mail
sales@midcointernational.com
ANSI Z21.17
CSA2.7
IS
THE
SOLE
SAFETY INFORMATION TERMS: The following terms are used to identify hazards, safety precaution of special notations
and have standard meanings throughout this manual. They are printed in all capital letters using a bold type face as shown
below, and preceded by the exclamation mark symbol. When you see the safety alert symbol and one of the safety information
terms as shown below, be aware of the hazard potential.
DANGER: Identifi es the most serious hazards which will result in severe personal injury or death.
WARNING: Signifi es a hazard that could result in personal injury or death.
CAUTION: Identifi es unsafe practices which would result in minor personal injury or product and property damage.
As an ISO 9001:2008 certifi ed company, we proudly design, manufacture and assemble our products in Chicago, Illinois, USA.
Quality Designed for Proven Performance
Economite
RE4400DS HTD
Gas Burner
WARNING: If the information in these instructions
is not followed exactly, a fi re or explosion may result,
causing property damage, personal injury or death.
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately phone your gas supplier from another
building. Follow the gas supplier's instructions. If
you cannot reach your gas supplier call the fi re
department.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
AVERTISSEMENT. Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d'incendie ou d'explosion pouvant
entraîner des dommages matériels, des blessures ou la mort.
Ne pas entreposer ni utiliser d'essence ni d'autres vapeurs ou liquides
infl ammables à proximité de cet appareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir des téléphones
se trouvant dans le bâtimentoù vous êtes.
• Appelez immédiatement votre fournisseur de gaz depuis un voisin.
Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service
des incendies
L'installation et l'entretien doivent être assurés par un installateur ou
un service d'entretien qualifi é ou par le fournisseur de gaz.
BURNER MODEL:
___________________________________
BILL OF MATERIAL
NUMBER:
___________________________________
SERIAL NUMBER #: ___________________________________
WIRING DIAGRAM: ___________________________________
718
8471 50
Printed in USA

Advertisement

loading
Need help?

Need help?

Do you have a question about the ECONOMITE RE 4400DS HTD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Midco ECONOMITE RE 4400DS HTD

  • Page 1 NUMBER: ___________________________________ AVOID ERROR IN PARTS SELECTION. When ordering use complete MIDCO Part Number and Description. Furnish Burner Model Number, Bill of SERIAL NUMBER #: ___________________________________ Material Number and Serial Number (if available) from the specifi cation plate found on the product.
  • Page 2: Specifications

    Electronic Control to malfunction. Each installation must include suitable limit control(s). CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. 8471 50 MADE in the Midco Inc. International...
  • Page 3 (.6 - 60 SEC ) Y/BK LEGEND TIMER RELAY (NEUT) (HOT) WIRING AND COMPONENTS: ELECTRONIC CONTRO (.6 - 60 SEC ) 24V RELAY SOLID: BY MIDCO (30 SEC PRE-PURGE NOTE 2 24V RELAY BY INSTALLER TERMINALS: VALVE TIMER VALVE COMPONENT...
  • Page 4 When the burner is installed in the vestibule of jacketed equipment, it is recommended that the Automatic Safety Shut-Off Valve be left adjacent to the burner within the vestibule and the Main Manual Shut-Off Valve be installed outside. 8471 50 MADE in the Midco Inc. International...
  • Page 5 Leakage will be indicated by the appearance of soap bubbles. Locate and correct all gas leaks before proceeding. WARNING: DO NOT USE OPEN FLAME. 8471 50 MADE in the Midco International Inc.
  • Page 6 9. Check the draft control, if equipped with one, to make sure there is no spillage of fl ue products into the room. __________________________________________ 8471 50 MADE in the Midco Inc. International...
  • Page 7: Cartridge Assembly

    Outlet pressure settings must be checked while the gas is fl owing. To adjust outlet pressure, remove the seal cap for access to the adjusting screw. Turning the screw clockwise will increase outlet pressure, counter clockwise will decrease outlet pressure. __________________________________________ 8471 50 MADE in the Midco International Inc.
  • Page 8 VIII Sequence of The Midco RE4400DS is supplied with two timers to provide high fi re purge and low fi re start. With power applied to L1 and L2 the blower motor starts. Once the blower motor starts the blower air Operation switch closes.
  • Page 9 Special equipment, either factory or contractor installed, may cause variation in the procedures and Equipment descriptions given in this manual. (OEM Versions) Consult the OEM’s manual to identify the diff erences in the information. __________________________________________ 8471 50 MADE in the Midco International Inc.
  • Page 10: Warranty

    If a part is defective due to workmanship or materials and the part is removed from the product within the applicable warranty period and returned to Midco in accordance with the procedure described below, Midco will at its option either repair or replace the part.
  • Page 11 Final disposition of any warranty claim will be determined solely by Midco. If an inspection by Midco does not disclose any defect covered by this warranty, the product will be returned, scrapped, repaired, or replaced as instructed by the customer. Products returned to the customer will be sent shipping charges collect.
  • Page 12 FOLD LINE PLACE STAMP HERE Midco International Inc. Attn: Warranty Department 4140 West Victoria Street Chicago, Illinois 60646 FOLD LINE Midco ® International Inc. - 4140 West Victoria Street - Chicago, Illinois 60646 - toll free: 866 705 0514 9001 8470 50 tel: 773.604.8700 - fax: 866.580.8700 - web:...