Sapcon COAT-ENDURE Instruction Manual

Sapcon COAT-ENDURE Instruction Manual

Admittance level limit switch
Hide thumbs Also See for COAT-ENDURE:

Advertisement

Quick Links

INSTRUCTION MANUAL
COAT-ENDURE
Admittance Level Limit Switch
Version 2.3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the COAT-ENDURE and is the answer not in the manual?

Questions and answers

Summary of Contents for Sapcon COAT-ENDURE

  • Page 1 INSTRUCTION MANUAL COAT-ENDURE Admittance Level Limit Switch Version 2.3...
  • Page 2: Table Of Contents

    13 Product Selection Order Code ..........Sapcon Instruments Pvt.Ltd.
  • Page 3 Coat-Endure ........
  • Page 4 Error Indication ........... Sapcon Instruments Pvt.Ltd.
  • Page 5: Revision History

    • Copyright: All content on this document, such as text, graphics, logos and images is the property of Sapcon Instruments Pvt. Ltd. The selection, arrangement and presentation of all materials on this document and the overall design of this document is the exclusive property of Sapcon Instruments Pvt.
  • Page 6: Introduction

    User Manual & Datasheet V 2.3 1 Introduction 3 Features Coat-Endure is a microcontroller based compact coat im- • Universal power supply of 18 - 55 V DC and 90 - 265 mune admittance level limit switch. It is a compact level V AC on the same terminal.
  • Page 7: Electrical Specifications

    Up to 10 bar Mounting • Screwed: 1/2",1”,1 1/2", 3/4” BSP / NPT • Flanged: As per user specification Probe Length 65 mm and (85 mm to 1500 mm) Insulation Part PTFE / Full PTFE Table 2: Mechanical Specifications Sapcon Instruments Pvt.Ltd.
  • Page 8: Application Specifications

    Coat-Endure User Manual & Datasheet V 2.3 • The Coat-Endure probe can be installed in the ves- 7 Application Specifications sel in both horizontal (side mounting) and vertical (top mounting) positions. Please refer to Figures 3 and 4. Please refer to Table 3 for Application Specifications.
  • Page 9: Calibration And Settings

    Use external line suppressors and fuse wires to con- Calibration for Non-Conductive Materials tain the risk of damage to the circuit. Coat-Endure needs to be calibrated inside the empty pro- cess tank (i.e only air, no material). Calibrating the instru- COAT-ENDURE ment outside the tank can cause malfunctions.
  • Page 10: Factory Reset

    This time is called COVER Delay. For a different value of Cover Delay, the number of blinks can be adjusted as per requirement. 5. To test, dip coat-endure into the application material until the switching point is reached. Note:...
  • Page 11: Sensitivity Adjustment

    7. Set the CALIBRATE and UNCOVER switches back to OPEN position. Figure 11: Setting Uncover Delay 8. Check operation of Coat-Endure by filling in and drain- ing out the material. 4. Uncover Delay is entered, but not saved. To save and test the Uncover Delay, set the UNCOVER switch back 9.
  • Page 12: Error Indication

    Fail-safe switch can be OPEN or CLOSE and is not a source of error. Resetting Error: 1. Bring the CALIBRATE, COVER and UNCOVER switches to OPEN position. 2. Press the ENTER key. 3. LED alternate color blinking will STOP. Sapcon Instruments Pvt.Ltd.
  • Page 13: Maintenance

    Thank you for going through the instructions given in this manual. To further ease the process of installation and use, we have developed special demo videos which are hosted on YouTube. Sapcon’s YouTube channel, SAPCON INSTRUMENTS, lists all these videos: https://goo.gl/dnxfcz Should you require further information regarding installation, use or working of the instrument, please don’t hesitate to contact us.
  • Page 14: Product Selection Order Code

    MN15S6 : Screwed Thread, NPT 1-1/2”, SS 316 F10S4 : 1" ASA Flange, 10mm thickness, SS 304 F10S6 : 1” ASA Flange, 10mm thickness, SS 316 F15S4 : 1-1/2” ASA Flange, 10mm thickness, SS 304 F15S6 : 1-1/2” ASA Flange, 10mm thickness, SS 316 Sapcon Instruments Pvt.Ltd.
  • Page 15 Standoff Material (Only with “25T”) STGI : GI (Galvanized Iron) STS4 : SS 304 STS6 : SS 316 Probe Length 0.65H : 65mm 0.85H1.5H : 85mm to 150mm 1.5H15H : 151mm to 1500mm Example - CE-I-SCUTE-PCPG13-D-U-P-MB10S4-S20S4-SH11S4-10T-0.65H Shows First Priority Entity Sapcon Instruments Pvt.Ltd.

Table of Contents