Sapcon Vital Instruction Manual

Sapcon Vital Instruction Manual

Compact vibrating fork level switch

Advertisement

Quick Links

INSTRUCTION MANUAL
VITAL
Compact Vibrating Fork Level Switch
Version 2.3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vital and is the answer not in the manual?

Questions and answers

Summary of Contents for Sapcon Vital

  • Page 1 INSTRUCTION MANUAL VITAL Compact Vibrating Fork Level Switch Version 2.3...
  • Page 2: Table Of Contents

    17 Product Selection Order Code ..........Sapcon Instruments Pvt.Ltd.
  • Page 3 List of Figures Vital Product Image ..........
  • Page 4: Revision History

    Secure the cover of housing tightly. Tighten the cable glands. For side mounting, the cable glands should point downwards. • For side mounting, provide a baffle to prevent the material from falling on the probe. • Make all electrical connections as instructed in the manual. DO NOT power on the device before verifying the connections. Sapcon Instruments Pvt.Ltd.
  • Page 5: Introduction

    • Self-diagnosis. 1 Introduction • External LED indication available with WL option Vital is a vibrating fork level limit switch for free-flowing ≤ 12 solids having a maximum granule size mm. It is suit- • Independent of material’s electrical properties.
  • Page 6: Electrical Specifications

    Response Time with ’NS’ option • Cover Delay : 1-2 second • Uncover Delay : 1-3 seconds Response Time with ’FS’ option • Cover Delay : 1 second • Uncover Delay : 0.8 seconds Table 2: Application Specifications Sapcon Instruments Pvt.Ltd.
  • Page 7: Mechanical Specifications

    Make all electrical connections as instructed in the manual. Don’t power on the device before verifying the connections. • To prevent the ingress of moisture and water seepage in side mounting position, the cable entries should always point downwards. Sapcon Instruments Pvt.Ltd.
  • Page 8: Electrical Connections

    L (Live) L (Live) N (Neutral) N (Neutral) 90-265 V AC 18-55 V DC 90-265 V AC 18-55 V DC (a) Electronics option SPDT Relay and (b) Electronics option DPDT Relay(D) PNP Output(SPN) Figure 5: Electrical Connections Sapcon Instruments Pvt.Ltd.
  • Page 9: Sensitivity Settings

    Figure 12. The STATUS LED will FAILSAFE GREEN come back to its original position. Figure 8: Setting Sensitivity Value 5. To test, dip vital into the application material until the switching point is reached. Sapcon Instruments Pvt.Ltd.
  • Page 10: Uncover Delay

    Figure 15: Saving Uncover Delay during switching. A maximum of 25 seconds can be set. 12 Uncover Delay 5. To test, dip vital into the application material until the switching point is achieved. When the application material uncovers vital’s fork tines, the changeover of the output can be delayed by a pre- 6.
  • Page 11: Troubleshooting & Indications

    – In failsafe ’Low’ mode, instrument will switch to NORMAL 15 Maintenance The electronics of Vital instrument needs no mainte- nance. When cleaning and checking the vessel, free the tuning fork from deposits. If the material has tendency to form a hard sticky deposit, the instrument must be checked more often.
  • Page 12: Product Selection Order Code

    User Manual & Datasheet V 2.3 17 Product Selection Order Code Product VITAL : Compact Vibrating Fork Type Level Limit Switch for free flowing solids, granules and powders Type I : Integral (sensor in same unit) Housing SCUTE : Pressure Die Cast Aluminium weather proof (Rating IP-68) SCUTE FP2C : Cast Aluminium weather &...
  • Page 13 2H30H : 200 to 3000 mm (Only with “VF130”, “VF185”) (Only with “Flange Mounting”) 2H : 200 mm (Only with “VF185”) 2.5H30H : 250 to 3000 mm (Only with “VF185”) (Only with “Screwed Mounting”) VITAL-I-SCUTE-PCPG13-D-U-NS-MB15S4-VF185-HB-10T-2H Example - Shows First Priority Entity Sapcon Instruments Pvt.Ltd.

Table of Contents