15.5 Timers

The control unit shows the timers that are in operation.
There are a number of timers for, e.g., delays of different
types, but also for extra hot water, hot water peak, etc.
A number of these times are set under customer or
Timers
Extra hot water
Hot water peak time for warm-keeping
Alarm mode delay
Party
Operating time for heating at hot water demand
Hot water, operating time at heating demand
Heat pump x timers
> Compressor start delay
> Compressor start delay groundwater
> G2 heat carrier pump stop delay
> Block low pressure switch
> Compressor working area timers
>> Block after hot water production
>> Delay after temporary stop
>> Block after low outdoor temperature
Additional heat timers
> Additional heat start delay
> Additional heat start delay after high outdoor
temperature
Delay before change over to summer operation
Delay before change over to winter operation
Shut down protection during change over from hot
water to heating
*)
Heating start delay
*)
Heating stop delay
Tab. 111Timers
*)
Delay between compressors start/stop for heating with two compressors/heat pumps.
6 720 643 409 (2010/03)
installer, whereas others have a set factory value which
cannot be changed. Level shows at what level the setting
can be made. 0 = Customer, 1 = Installer, 3 = Factory.
Setting
Extra hot water duration
Hot water\Hot water peak\Time for warm-
keeping
Party (
)
Room temperature\General\Maximum operating
time for heating at hot water demand
Hot water\Maximum operating time for hot
water at heating demand
Heat pump\Groundwater\Compressor start
delay
Additional heat\Additional heat general\Start
delay
Additional heat\Additional heat
general\Additional heat start delay after high
outdoor temperature
Room temperature\General\Summer/winter
operation\Delay before change over to summer
operation
Room temperature\General\Summer/winter
operation\Delay before change over to winter
operation
Room temperature\General
Settings
F value
Level
0h
0, 1
1.0h
1
1.0h
3
0h
0
20min
0
30min
0
10min
3
0s
1
5mins
3
150s
3
120s
3
30min
3
30min
3
60min
1
30min
1
4h
1
4h
1
300s
1
3min
-
3min
-
69