Toro Pro Sneak 365 Operator's Manual page 36

Vibratory plow
Hide thumbs Also See for Pro Sneak 365:
Table of Contents

Advertisement

8.
Clean up any spilled fluid.
9.
Start the engine and let it run for about 2 minutes
to purge any air from the system.
10.
Shut off the engine and check for leaks.
Checking the Hydraulic-Fluid
Level
Service Interval: Before each use or daily
Important:
Always use the correct hydraulic
fluid. Unspecified fluids will damage the hydraulic
system.
1.
Park the machine on a level surface, and lower
any attachments.
2.
Shut off the engine, remove the key, and allow
the engine to cool.
3.
Open the hood.
4.
Clean the area around the filler neck of the
hydraulic tank.
CAUTION
During regeneration, the diesel
particulate filter becomes extremely hot
and can cause serious burns.
Keep your body and hands away from
the engine during regeneration.
5.
Remove the cap from the filler neck and check
the fluid level on the dipstick
The fluid level should be between the marks on
the dipstick.
1. Filler neck
6.
If the level is low, add enough fluid to raise it to
the proper level.
(Figure
41).
Figure 41
2. Dipstick
7.
Install the cap on the filler neck.
8.
Close the hood.
Changing the Hydraulic Fluid
Service Interval: After the first 250 hours
Every 1,000 hours/Yearly (whichever comes
first)
1.
Position the machine on a level surface.
2.
Remove the upper left panel of the console
(Figure
42).
1. Hydraulic tank
3.
Place a large drain pan (capable of holding 57
liters (15 US gallons) on the ground under the
hydraulic tank.
4.
Remove the hydraulic tank cap and use a pump
to empty the hydraulic tank.
5.
Remove the lower right side cover plate and
loosen the hose clamp holding the suction hose
to the hydraulic tank
g023716
36
Figure 42
2. Upper left panel
(Figure
43).
g026499

Advertisement

Table of Contents
loading

This manual is also suitable for:

25403