FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
The 50M58-289 is a replacement control for two-stage automatic
gas ignition controls employing a microprocessor to continually
monitor, analyze, and control the proper operation of the gas
burner and inducer. The 50M58-289 controls a multiple tapped
induction circulation blower.
Signals interpreted during continual surveillance of the two-
stage thermostat and flame sensing element initiate automatic
Installation should be done by a qualified heating and air
conditioning contractor or licensed electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes
and ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.
Following installation or replacement, follow manufacturer's
recommended installation/service instructions to ensure proper
operation.
CAUTION
!
Do not short out terminals on gas valve or primary
control. Short or incorrect wiring may damage the
thermostat.
CONTENTS
Description ............................................................. 1
Precautions ............................................................ 1
Specifications ......................................................... 2
Installation .............................................................. 3
Operation ................................................................ 6
2-Stage, X-13 Style Hot Surface Ignition Control
INSTALLATION INSTRUCTIONS
ignition of the burner, sensing of the flame, and system shutoff
during normal operation.
The control incorporates system fault analysis for quick gas
flow shutoff, coupled with automatic ignition retry upon sensing
a fault correction.
Failure to comply with the following warnings could
result in personal injury or property damage.
FIRE HAZARD
• Do not exceed the specified voltage.
• Protect the control from direct contact with water
(dripping, spraying, rain, etc.)
• If the control has been in direct contact with water,
replace the control.
• Label all wired before disconnection when servicing
controls. Wiring error can cause improper and
dangerous operation.
• Route and secure wiring away from flame.
SHOCK HAZARD
• Disconnect electric power before servicing.
• Ensure proper earth grounding of appliance.
• Ensure proper connection of line neutral and line
hot wires.
EXPLOSION HAZARD
• Shut off main gas to appliance until installation is
complete.
www.white-rodgers.com
www.emersonclimate.com
50M58-289
DESCRIPTION
PRECAUTIONS
WARNING
!
PART NO. 37-7547B
Replaces 37-7547A