OBJ_BUCH-487-003.book Page 17 Wednesday, December 9, 2015 11:29 AM
The vibration level given in this information sheet has been
measured in accordance with a standardised test given in
EN 60745 and may be used to compare one tool with anoth-
er. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main ap-
plications of the tool. However if the tool is used for different
applications, with different accessories or insertion tools or is
poorly maintained, the vibration emission may differ. This
may significantly increase the exposure level over the total
working period.
An estimation of the level of exposure to vibration should also
take into account the times when the tool is switched off or
when it is running but not actually doing the job. This may sig-
nificantly reduce the exposure level over the total working
period.
Identify additional safety measures to protect the operator
from the effects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work pat-
terns.
Declaration of Conformity
We declare under our sole responsibility that the product de-
scribed under "Technical Data" is in conformity with all rele-
vant provisions of the directives 2011/65/EU, until
19 April 2016: 2004/108/EC, from 20 April 2016 on:
2014/30/EU, 2006/42/EC including their amendments and
complies with the following standards: EN 60745-1,
EN 60745-2-1, EN 60745-2-2, EN 50581.
Technical file (2006/42/EC) at:
Robert Bosch GmbH, PT/ETM9,
70764 Leinfelden-Echterdingen, GERMANY
Henk Becker
Helmut Heinzelmann
Executive Vice President
Head of Product Certification
Engineering
PT/ETM9
Robert Bosch GmbH, Power Tools Division
70764 Leinfelden-Echterdingen, GERMANY
Leinfelden, 23.11.2015
Assembly
Battery Charging
Note: The battery supplied is partially charged. To ensure full
capacity of the battery, completely charge the battery in the
battery charger before using your power tool for the first time.
The lithium-ion battery can be charged at any time without re-
ducing its service life. Interrupting the charging procedure
does not damage the battery.
The lithium-ion battery is protected against deep discharging
by the "Electronic Cell Protection (ECP)". When the battery is
empty, the machine is switched off by means of a protective
circuit: The inserted tool no longer rotates.
 Do not continue to press the On/Off switch after the
machine has been automatically switched off. The bat-
tery can be damaged.
Bosch Power Tools
Removing the battery
The battery 8 is equipped with two locking levels that should
prevent the battery from falling out when pushing the battery
unlocking button 14 unintentionally. As long as the battery is
inserted in the power tool, it is held in position by means of a
spring.
To remove the battery 8:
– Push the battery against the base of the power tool (1.)
and at the same time press the battery unlocking button 14
(2.).
– Pull the battery out of the power tool until a red stripe be-
comes visible (3.).
– Press the battery unlocking button 14 again and pull out
the battery completely.
Battery Charge-control Indication (see figure A)
The three green LEDs of the battery charge-control indicator
12 indicate the charge condition of the battery 8. For safety
reasons, it is only possible to check the status of the charge
condition when the machine is at a standstill.
Push button 13 to indicate the charge condition (also possi-
ble when the battery is removed). The battery charge-control
indicator automatically goes out after approx. 5 seconds.
LED
Continuous lighting 3 x green
Continuous lighting 2 x green
Continuous lighting 1 x green
Flashing light 1 x green
When no LED lights up after pushing button 13, then the bat-
tery is defective and must be replaced.
During the charging procedure, the three green LEDs light up
one after the other and briefly go out. The battery is fully
charged when the three green LEDs light up continuously. The
three LEDs go out again approx. 5 minutes after the battery
has been fully charged.
Auxiliary Handle (see figure B)
 Operate your machine only with the auxiliary handle 7.
The auxiliary handle 7 can be set to any position for a secure
and low-fatigue working posture.
Turn the bottom part of the auxiliary handle 7 in counterclock-
wise direction and swivel the auxiliary handle 7 to the desired
position. Then retighten the bottom part of the auxiliary han-
dle 7 by turning in clockwise direction.
The clamping band 15 of the auxiliary handle must be seated
in the corresponding groove.
English | 17
Capacity
≥2/3
≥1/3
<1/3
Reserve
1 609 92A 1K9 | (9.12.15)