  • Page 1 PX091 Dimmer 12 x 1200 W MANUAL...
  • Page 2: Table Of Contents

    10. DMX signal connection..............11. Technical specification..............12. Declaration of conformity..............Manufacturer reserves the right to make modifications in order to improve device operation. PXM Marek Żupnik tel.: (+48 12) 626 46 92 Limited Partnership fax: (+48 12) 626 46 94 ul.
  • Page 3: General Description

    1. GENERAL DESCRIPTION PX091 is a professional AC class dimmer 12 x 1200 W powered with 3 phases, 2 phases or 1 phase. The dimmer controls 12 independent channels, 1.2 kW each. Advanced electronics allows to address easily each channel, to choose the control curve, to set output voltage limitation and preheat level and to determine dimmer answer for the interruption of the DMX control signal as well.
  • Page 4: Front Panel

    3. FRONT PANEL (CONTROL PANEL) Output channels LED indicators Display Power supply LED indicators DMX signal presence LED indicator Programming keys TEST key SETTINGS There are four buttons for dimmer programming: ENTER - starts programming mode and confirms settings NEXT - scrolls MENU forwards or increases values set PREV - scrolls MENU backwards and decreases values set...
  • Page 5: Programmable Parameters

    5. PROGRAMMABLE PARAMETERS The dimmer allows to define the following operation parameters: 1. The group parameters - menu Chosen settings are same for all channels. In case of the DMX address, the displayed value is related to the first channel. For all the other channels subsequent address values are assigned.
  • Page 6: Individual Parameters

    5.2. INDIVIDUAL PARAMETERS - DMX address. Chosen from the 1 - 512 range. - control curve choice. There are 8 options to choose from: - linear, - switchable, - inverted, - logarithmic, - exponential, - for neon lamps control. -limit. Limits the output voltage in the range from 50 - 230 V. 5.3.
  • Page 7: Switching The Access Lock Off

    6.2. SWITCHING THE ACCESS LOCK OFF 1. Refer to point 1 in the previous chapter. 2. Push ENTER button - the inscription will show. 3. Push button ENTER again - number will show. 4. Set the code using buttons "PREV" and "NEXT" and confirm it with the "ENTER" button. 5.
  • Page 8: Dimmer Description

    8. DIMMER DESCRIPTION Top panel - XLR sockets and fans Control panel S - C6 fuses Residual-current circuit breaker PX091 12 x 1200 W DMX OUT / IN sockets ADVANCED CONTROL (the sockets can be installed DIMMER inside the dimmer) Top panel 9.1.
  • Page 9: Power Cable Connection

    2. The device has to have properly connected the protective cable (yellow - green strand of the power cable). 3. The power circuit, where the PX091 dimmer is connected, must be equipped with the residual- current circuit breaker. 4. The minimal power cable cross-section area is 4 mm .
  • Page 10: Dmx Signal Connection

    10. DMX SIGNAL CONNECTION 1. ground 1. To connect devices use of the microphone cable is recommended (two strands in the shield). 3. DMX (+) 2. The devices should be connected in series. 3. To split the DMX line it is necessary to use the 2.
  • Page 11: Declaration Of Conformity

    30-701 Kraków, Poland fax: +48 12 626 46 94 DECLARATION OF CONFORMITY according to guide lines 2004/108/EC and 2006/95/EC PXM Marek Żupnik Limited Partnership Name of producer: ul. Przemysłowa 12 Address of producer: 30-701 Kraków, Poland declares that the product:...