Pentair Pool Products Delta D2CX20-21 Installation & Service Manual With Parts List page 15

Submersible centrifugal grinder pump
Table of Contents

Advertisement

Fig. 41
Fig. 42
Fig. 43
23833A596
14. Replace red and orange seal failure wires if
necessary. Loosen nut in seal chamber to
remove wire.
15. Put in new seal failure wires and adjust so that
the probe portion of the seal leak wires are
staggered, the end of the longest wire being up
¼" from the machined face of the casting. See
Figure 41. Position shorter lead above the first
so probes do not touch. See drawing front cover.
Retighten seal nut. Be sure rubber seal ring is in
place to seal wire. See Figure 42.
16. Using fine picture hanging wire pull seal failure
wire up through stator hole before replacing stator.
See Figure 43. The stator is pressed into housing
at the factory and is shipped as a unit. Do not try
to replace stator in housing in the field, they must
be replaced as a unit.
17. Using Allen wrench or small screwdriver in bolt
holes to hold parts in place, position upper
bearing casting upside-down and run wires down
through holes in segmented casting. Next apply
STP or equivalent to bearing cup liberally and
insert the first finger spring washer flat side down.
Apply more STP and insert second finger spring
washer flat side down, to make paired finger
washers. Apply STP again to hold washers in
place when casting is turned over and installed
on top of rotor. Bearing housing will be held off of
stator housing approximately
to touch stator housing when pushed downward.
See Figures 44, 45 and 46.
Fig. 4
Fig. 5
15
1
/
" and will depress
16

Advertisement