8.8 Check after Installation and Test
Operation
1. Check after Installation
Check according to the following requirement after finishing
installation.
NO.
Items to be checked
Has the unit been
1
installed firmly?
Have you done the
2
refrigerant leakage test?
Is heat insulation of
3
pipeline sufficient?
4
Is water drained well?
Is the voltage of power
supply according to the
5
voltage marked on the
nameplate?
Is electric wiring and
6
pipeline installed
correctly?
Is the unit grounded
7
securely?
Does the power cord
8
follow the specification?
Is there any obstruction
9
in air inlet and air outlet?
The dust and
sundries caused
10
during installation are
removed?
The gas valve and liquid
11
valve of connection pipe
are open completely?
Is the inlet and outlet
12
of piping hole been
covered?
2. Test Operation
(1) Preparation of test operation
● The client approves the air conditioner installation.
● Specify the important notes for air conditioner to the client.
(2) Method of test operation
● Put through the power, press ON/OFF button on the remote
controller to start operation.
● Press MODE button to select AUTO, COOL, DRY, FAN and
HEAT to check whether the operation is normal or not.
● If the ambient temperature is lower than 16℃ , the air
conditioner cant start cooling.
Installation and Maintenance
Possible malfunction
The unit may drop, shake or
emit noise.
It may cause insufficient cooling
(heating) capacity.
It may cause condensation and
water dripping.
It may cause condensation and
water dripping.
It may cause malfunction or
damage the parts.
It may cause malfunction or
damage the parts.
It may cause electric leakage.
It may cause malfunction or
damage the parts.
It may cause insufficient cooling
(heating) capacity.
It may cause malfunction or
damaging the parts.
It may cause insufficient cooling
(heating) capacity.
It may cause insufficient cooling
(heating) capacity or waster
eletricity.
39