Download Print this page

Honeywell AUDZBX75 Installation Manual page 2

A-bus source input module

Advertisement

(cont...)
Infrared (IR) Emitter Port [8]
This jack is provided for infrared control of the source component. It is a routed output that will only emit
commands from a Volume Control Module in a zone that has selected that source. Some components
have a 2-cond. IR input jack on the back. It is recommended that this direct connection be used.
CAUTION: Do not confuse a serial data port connection with an infrared port.
12v DC Trigger [12]
- This is a 12v DC output that turns on when that source is selected. The output
can be used to trigger a relay for power control of the source component.
CAUTION: Do not hook up devices to the Trigger that will exceed 50mA of current draw.
Audio Input [13]
- For connection to source component
Loop Out [14]
- To loop the same audio component source into a home theater receiver or an amplifier
Input Module
AUDZBX75
Inputs
Audio
Outputs
Audio
IR
Trigger
A-BUS
AUDZBX75 A-BUS Source Input Module
– This will accept a standard IR emitter with a 3.5mm 2-cond. mini plug.
Socket
8 7
6
5
4
3
Pin Signal
8
Brown
+24 Vdc
7
Brown & White
Ground
6
Orange
Right Channel
5
Blue & White
Status
4
Blue
IR
3
Orange & White
Right Ch. Ground
2
Green
Left Channel
1
Left Ch. Ground
Green & White
A-BUS Wiring Color Code (T568A)
A-BUS Source Input Module
1 x Stereo RCA Pair
1 x Stereo RCA Pair Loop Thru
1 x 3.5mm mini phono
1 x 3.5mm mini phono 12vdc +V Center 50mA
1 x Cat-5 110 Punchdown
A-BUS® is a Registered Trademark of LeisureTech Electronics Pty Ltd Sydney, Australia.