28. Ordering for Accessories

Accessories
GPS antenna and mounting details
GPS antenna, including mounting kits
Cable for antenna, 20 m (Appx. 65 ft)
Cable for antenna, 40 m (Appx. 131 ft)
Interface converter (for remote end data communication)
External interface converter from C37.94 (64kbps) to G703
External interface converter from C37.94 (64kbps/2Mbps) to G703.E1
Test switch
The test system COMBITEST intended for use with the
IEDs is described in 1MRK 512 001-BEN and 1MRK
001024-CA. Please refer to the website:
www.abb.com/protection-control
information.
Due to the high flexibility of our product and the wide
variety of applications possible the test switches needs
to be selected for each specific application.
Select your suitable test switch based on the available
contacts arrangements shown in the reference
documentation.
However our proposals for suitable variants are:
Two winding transformer with internal neutral on
current circuits. Two pcs can be used in applications for
three winding transformers in single or multi-breaker
arrangement (ordering number RK926 315-BD)
Protection cover
Protective cover for rear side of RHGS6, 6U, 1/4 x 19"
Protective cover for rear side of terminal, 6U, 1/2 x 19"
Protective cover for rear side of terminal, 6U, 3/4 x 19"
Protective cover for rear side of terminal, 6U, 1/1 x 19"
156
SEMOD111888-5 v13
for detailed
© Copyright 2017 Hitachi Power Grids. All rights reserved
Quantity:
Quantity:
Quantity:
Quantity :
Quantity :
Two winding transformer with external neutral on
current circuits. Two pcs can be used in applications for
three winding transformers in single or multi-breaker
arrangement (ordering number RK926 315-BH).
Three winding transformer with internal neutral on
current circuits (ordering number RK926 315-BX).
The normally open "In test mode" contact 29-30 on the
RTXP test switches should be connected to the input of
the test function block to allow activation of functions
individually during testing.
Test switches type RTXP 24 is ordered separately. Please
refer to Section
Related documents
corresponding documents.
RHGS 6 Case or RHGS 12 Case with mounted RTXP 24
and the on/off switch for DC-supply are ordered
separately. Please refer to Section
for references to corresponding documents.
Quantity:
Quantity:
Quantity:
Quantity:
1MRK 502 074-BEN M
IP15151-1 v1
M12374-3 v5
1MRK 001 640-AA
1MRK 001 665-AA
1MRK 001 665-BA
M16668-3 v10
1
2
1MRK 002 245-AA
1
2
1MRK 002 245-BA
for references to
Related documents
M15040-3 v8
1MRK 002 420-AE
1MRK 002 420-AC
1MRK 002 420-AB
1MRK 002 420-AA
Hitachi Power Grids

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents