7. Select the item number 2244, and turn off the power supply of
battery terminal.
8. Press the
key to select the item number 2245.
>
9. Adjust with [VOL+]/[VOL--] keys so that the voltage of between
CL935 and CL433 (GND) becomes 1.80 V (− 0.02 V).
10. Apply the voltage of 1.2 V to the battery terminal again.
11. Turn off the voltage of 5 V to the CL453 and CL460 (GND).
12. Press the
key three times and back to the Display Check
x
mode.
3-4. Laser Power Check
Procedure:
1. Enter the test mode (Display Check mode).
2. Press the [VOL+] key to enter the Manual mode.
3. Open the lid and press the
optical pick-up moves to the most inward track.
4. Press the [VOL--] key once to display as follows.
Display
9000
DESIGN
5. Press the
key three times to select the item number 9111
>
and display as follows.
Display
9111
LrefPw **
6. Set the laser power meter so that the laser beam from the optical
pick-up aims at the objective lens of laser power meter at right
angle. (Confirm it with the disc not inserted)
7. Confirm that the value of laser power meter is 0.860 mW ±
19.2%.
8. Press the
key to select the item number 9112.
>
9. Confirm that the value of laser power meter is 0.763 mW ±
18.2%.
10. Press the
key to select the item number 9113.
>
11. Confirm that the value of laser power meter is 6.87 mW ±
12%.
12. Press the
key four times and back to the Display Check
x
mode.
3-5. Setting The Adjustment Values
3-5-1. Hi-MD3 setting
Preparation:
1. Perform calculation every item based on the data given by the
Hi-MD3 adjustment disc by referring to the following table.
(Round off the value in decimal place)
2. Convert the calculated value into hexadecimal number.
Note: The Hi-MD3 adjustment parameters vary depending on the disc,
and therefore use the parameters of the disc used when performing
the adjustment.
Item No.
Calculating formula (*3)
0211
Pr_nominal / 0.05
(*1)
Por / 0.05
Kr × (−100)
0212
0213
Pw_nominal / 0.05
(*2)
Ppw / 0.05
Kw × (−100)
0214
0215
Prmin / 0.05
0216
Pwmin / 0.05
18
key continuously until the
.
*1) If the "Pr_nominal" value is indicated, use the "Pr_nominal" value
and not used "Por" value.
*2) If the "Pw_nominal" value is indicated, use the "Pw_nominal" value
and not used "Ppw" value.
*3) Round off after the decimal point.
Table 3-5-1. Hi-MD3 adjustment parameter
Example of Calculation:
Item No.
Parameter
0211
Pr_nominal
2.48 mW
−0.3 %/°C
0212
Kr
0213
Pw_nominal
7.35 mW
−0.4 %/°C
0214
Kw
0215
Prmin
1.9 mW
0216
Pwmin
5.8 mW
Procedure:
1. Enter the test mode (Display Check mode).
2. Press the [VOL+] key to enter the Manual mode.
key once, press the [VOL+] key once, and press
3. Press the
>
the
key once again to display as follows.
>
Display
0210
DiscPr
4. Press the
key once to select the item number 0211.
>
5. Adjust with [VOL+]/[VOL--] keys so that the adjustment value
of LCD becomes calculated value.
6. Press the
key to write the adjusted value.
X
7. Press the
key to next item.
>
8. Repeat adjustment from step 4 until item number 0216.
3-5-2. Destination setting
Procedure:
1. Enter the test mode (Display Check mode).
2. Press the [VOL+] key to enter the Manual mode.
3. Press the
key five time to select the item number 0113
>
and display as follows.
Display
0113
DistFL **
adjustment value (hexadecimal)
4. Press the [VOL+]/[VOL--] key and set the according value to
each destination referring to the following table.
5. Press the
key to write the adjusted value.
X
6. Press the
key to select the item number 0114.
>
7. Repeat adjustment from step 3.
8. Press the
key four times and back to the Display Check
x
mode.
Destination
US and Canadian
Table 3-5-2. Destination Setting
Result
Decimal
Hexadecimal
50
32h
30
1Eh
147
93h
40
28h
38
26h
116
74h
Setting value
Item No. 0113 Item No. 0114