Download Print this page

Case IH AFS Pro 700 Quick Reference Card page 4

Accucontrol liquid toolbar
Hide thumbs Also See for AFS Pro 700:

Advertisement

7 - ovERlaP/boUNdaRY CoNTRol – continued
7.2 Product delay adjustment – continued
g) Press the 'Start' button
on the display and at
the same time, start the
stopwatch.
h) Stop the stopwatch
when product is first
observed leaving the
application point.
i) The elapsed time
displayed on the
stopwatch is the
Product Delay.
j) Exit the calibration
without updating the
calibration number by
pressing 'Back'.
k) Press 'Liquid' Tab
l) Enter the measured time
as the Product
Delay figure.
m) Throughout the season
check for proper
overlap operation
n) If exact measurement of
error is determined use
this formula to convert
this distance to a new
Product Delay (PD).
In. of error
= new PD (sec)
mph X 17.52
o) Adjust Start Early/Stop Late distance for intentional overlap.
If a negative number seems to be required for SE/SL, re-
measure & adjust Product Delay
7 - ovERlaP/boUNdaRY CoNTRol – continued
7.3 Running overlap/boundary Ctrl
NoTE! The following windows can be located
on the Run screens.
Disengages drive section master valve
and/or all boom valves for that drive
section. "On" when the button is black
(1), and "Off" when the button is grey (2)
Enables/Disables
Boundary Control
Enables/Disables Overlap Control
(disable before backing, enable after
driving forward), except AccuGuide
complete tractors
Disengage individual
boom valves
Quickly switch between Auto
and Manual section control
NoTE! (A) must be present for Auto Overlap and Boundary
Control to function. If (M) is present, Auto Overlap and
Boundary control will not work!
TIPS
1) A data card must be inserted in to the display.
2) Check GPS Offset, Bar Distance, Product Delay, and check that a product is
assigned to a layer for Overlap & Boundary control to function properly.
3) "(A)" must be present in a window for Auto mode.
4) Disable Overlap Ctrl before backing into corners, etc. Re-enable after
moving forward. Turning off Overlap Control before backing up is not
required with tractors that have Case IH Factory AccuGuideAutoGuidance.
AFS-8035-13e
Replaces: None
© 2013 CNH America LLC. All rights reserved. Printed in U.S.A.
Case IH is a registered trademark of CNH America LLC. Any trademarks referred to herein in
association with the goods and/or services of companies other than CNH America LLC are the
property of those respective companies.
CNH America LLC reserves the right to make improvements in design and changes in
specifications at any time without notice and without incurring any obligation to install
them on units previously sold. Specifications, descriptions and illustrative material herein
are as accurate as known at time of publication, but are subject to change without notice.
Availability of some models and equipment builds varies according to the country in which
the equipment is used.
Visit us on the web at www.caseih.com

Advertisement

loading