Download Print this page

Case IH AFS Pro 700 Quick Reference Card page 2

Accucontrol liquid toolbar
Hide thumbs Also See for AFS Pro 700:

Advertisement

3 – lIQUId ToolbaR CoNfIGURaTIoN – continued
3.5 Master Switch box
(If equipped with External Switch box)
a) Select Master Sw
Box [Yes]
b) Press 'Setup'
c) Verify Serial Number of
Switch Box
d) Select Footswitch
(if installed)
e) Press "Done'
Note: Rate 1/Rate2/
Manual Switch is not
functional. All others
are functional.
3.6 Implement Switch
(If equipped with Toolbar Mounted Implement Switch)
a) Select Imp
Switch [Yes]
b) Press 'Setup'
c) Select Imp Switch
Serial Number
d) Select Switch Polarity
Note: Determine by
raising and lowering the
implement and watch the
Implement Status Arrow
in Status/Warning Area
for proper operation.
e)Press 'Done'
3.7 Section Switch box (If equipped with
External Section Switch box or desire Manual valve
Section Control through Run Screens)
a) Select Section
Switch Box [Yes]
b) Press 'Setup'
c) Select Config Mode
[Auto] or [Manual]
for custom
d) Verify Sw Box
Serial Number
(if equipped w/
external switchbox)
Note: If no external switchbox is installed, User Defined
Windows can be assigned to a Run Screen (Toolbox>layout).
4 – WoRk CoNdITIoN – REQUIREd foR oPERaTIoN
Work Condition>layer
IMPoRTaNT! The settings below are linked to a
work condition. These must be selected or checked
whenever a work condition is created/changed: product type,
application rate, drive settings, product delay (w/ as applied),
product layer control (w/ as applied), and product control.
NoTE! A work condition name could be the current work
practice, crop type (corn, soybeans, etc), seed size, field
condition, or weather condition, etc.
NoTE! This setup is required for logging/ mapping data and
using Overlap & Boundary Control.
4.1 Preparation
a) Insert a data card in the display
b) Create/select a Grower/Farm/Field/Task and Crop Type
(Performance > Profile)
4.2 Product Setup
Toolbox>Product
a) Name the product
(ex. 32-0-0)
b) Select Form Type for
Product [Liquid]
c) Select Product Usage
d) Enter Default
Application rate
e) Enter Minimum
application rate
& Maximum
application rate
NoTE! Rate will not be able to be adjusted outside of this range.
f) Create additional products (liquid, etc.) as needed.
4 – WoRk CoNdITIoN (continued)
4.3 Product layer assignment
Work
Condition>
layer
Assign a product to a control
ator.
section of the Applic
a) Select/create a work
condition.
b) Select Layer 1
Control Type
[AccuControl Liquid].
c) Select Product for
Layer 1 Control.
d) Assign Additional Layers as needed
4.4 Controller Setup liquid – (if equipped)
Work
Condition>
Control
a) Verify Implement
b) Verify Work Condition
c) Select Controller [Liquid]
d) Product Delay – Default
2.0 sec.
(see section 7
for Product Delay
Measurement procedure)
e) Enter the Minimum Speed
(if ground speed drops
below this speed, sprayer will apply at this set speed)
f) Enter value for Off-target Alarm Limit
5 – CalIbRaTIoNS (If equipped with liquid Rate Control)
5.1 valve Calibration
Work
Condition>
valve Cal
Note: Vehicle & controlling
components should be at
normal operating temp/
conditions for these
calibrations.
a) Select Drive Number
to Calibrate
b) Press 'Start' for Automatic
Valve Calibration
c) Repeat any other Drives

Advertisement

loading