Download Print this page

Case IH AFS Pro 700 Quick Reference Card page 3

Accucontrol liquid toolbar
Hide thumbs Also See for AFS Pro 700:

Advertisement

5 – CalIbRaTIoNS
(If equipped with liquid Rate Control) – continued
5.2 liquid Calibration
Work Condition>liquid Cal
a) Verify Implement
b) Verify Work Condition
c) Select Liquid Op
Mode – [Liquid]
(Accept Safety
Warning if agreed)
d) Press Master Control –
'Apply' Button
e) Press 'Next'
f) Verify Control Module
Serial Number
g) Verify Meter Cal
Value (change in
Toolbox>AccuCtrl>
Liquid Drive Setup)
h) Enter Simulated
Speed (Typical
Application Speed)
i) Enter Target Rate
j) Prime System
k) Press 'Next'
l) Place Catch Buckets
Under Each Valve
Section of Applicator
m) Press the 'Start'
Button & Allow
Product to Flow
n) Manually Measure
Collected Product and
Calculate Total Amount
Applied Across Entire
Width of Drive Section
(in Gal or L)
o) Enter [Actual Output]
p) Press 'Update'
Button to Update
the Meter Value
q) Repeat if Needed.
Record calibration values here, if desired
USaGE
Cal valUE
6 – oPERaTIoN
6.1 Enable Spraying
Run screens
Note: Most windows will need to be placed on
the run screen (Toolbox>layout)
a) Liquid Op Mode -
Select [Liquid]
b) Read Safety message &
press 'Accept' if agreed
c) Master Control – Press
'Apply' on display or
switch on master switch
on switchbox (if equipped)
6.2 liquid Rate Control (If equipped)
a) 'Liq Ctrl' Defaulted to 'On'
b) Increase or decrease rate, if needed
c) Automatic rate control (prescription) assigned in
Performance>Rx Setup
Current Rate
Increase
Decrease
6.3 Prime Control (If equipped w/ liquid Ctrl)
Prime is used to fill the system so no gap is left in the
field when starting.
Note: Window may not be available in v28.* software
versions. If not available, use the start button found in
Toolbox>liquid Cal to prime.
a) Press the Prime
button for 3 sec.
b) Wait for prime icon
in warning area to
stop flashing
c) System is primed
7 - ovERlaP/boUNdaRY CoNTRol
7.1 overlap/boundary Control
Toolbox> overlap
a) Turn overlap
control on.
b) Turn boundary
control on (requires a
created boundary)
c) Set % for out of
bounds.
d) Set % of overlap
for shutoff.
e) Set start early
distance to 0 ft
f) Set stop late
distance to 0 ft.
IMPoRTaNT! Product delay must be measured and set
correctly before adjusting start early/stop late values.
7.2 Product delay adjustment
Work Condition>Control>liquid
Exit to
before making any adjustments to the
save change
Product Delay, make sure GPS offsets &
Bar Distance are entered correctly.
To check performance:
Note: Prime can be used to perform this calibration (start at step h), but
Use Default
may not be available on the run screens. The liquid calibration screen
Rate
will be used to check the product delay in this case. Instructions below
Product
are for using the liquid calibration method.
On / Off
a) Select Work
Condition>Liquid Cal
b) Select Liquid Op Mode
– [Liquid] (Accept Safety
Warning if agreed)
c) Press Master Control –
'Apply' Button
d) Press 'Next'
e) Enter Simulated Speed
(Typical Application
Speed)
f) Enter Target Rate and
press 'Next'
continued on next page

Advertisement

loading