Typical Installation - American Standard Standard Residential Operating, Installation And Service Manual

Power vent gas water heater with vaporshield technology
Table of Contents

Advertisement

3
HOT OUTLET WATER
DRIP LEG (SEDIMENT TRAP)
MINIMUM LENGHT 3"
CAP
TEMPERED
WATER
(TO FIXTURES)
FOLLOW THE TEMPERING VALVE
MANUFACTURER'S INSTRUCTION
TYPICAL
DRAIN PAN MUST
LIMIT WATER
COLD
ACCUMULATION
TO A MAXIMUM
HEIGHT OF 1 3/4"
TEMEPRING
FIGURE 4
VALVE
(SET TO 120ºF)
INSTALLATION
CLOSED WATER
SYSTEM
EXPANSION
TANK
COLD
WATER
INLET
VALVE
TEMPERATURE AND PRESSURE RELIEF VALVE
**SOME MODELS MAY HAVE TEMPERATURE & PRESSURE RELIEF
VALVE TAPPING ON TOP OF HEATER
DATA PLATE AND LIGHTING
INSTRUCTION LOCATION
GAS CONTROL VALVE (THERMOSTAT)
DISCHARGE LINE (EXTEND TO AN OPEN DRAIN)
IT MUST BE AT LEAST 3/4" IN AND PITCHED FOR PROPER
DRAINAGE TO AN OPEN DRAIN. DO NOT THREAD, CAP
OR PLUG THE END
AIR GAT 6" MINIMUM
DRAIN LINE
SHOULD BEAT LEAST 3/4" IN AND
PITCHED FOR PROPER DRAINAGE
TO AN OPEN DRAIN
PIPING MUST MEET ALL LOCAL CODE REQUIREMENTS.
NOTE: Water heater must be installed level.
PRESSURE REDUCING
VALVE WITH BYPASS
COLD WATER
INLET
State of California Note:
The water heater must be braced, anchored,
or strapped to avoid moving during an earth-
Contact local utilities for code requirement
in your area or call 1-888-883-0788 and
request instructions.
quake.