Connect The Cable To The Outdoor Unit - Panasonic CU-4E23QBR Service Manual

Table of Contents

Advertisement

11.5 Connect the Cable to the Outdoor Unit

1. Remove the particular plate from the unit by
loosening two screws.
2. Cable connection to the power supply through
Isolating Devices (Disconnecting means).
Connect approved type polychloroprene
o
sheathed power supply cord
CU-4E27*** (3 x 2.5 mm
(3 x 4.0 mm
designation or heavier cord to the
terminal board, and connect the others
end of the cord to Isolating Devices
(Disconnecting means).
3. Connection cable between indoor unit and
outdoor unit shall be approved
polychloroprene sheathed 4 x 1.5 mm
cord, type designation 60245 IEC 57 or
heavier cord. Allowable connection cable
length of each indoor unit shall be 30 m or
less.
Remarks:
It is the responsibility of the installer or user of the equipment to ensure, by consultation with the suitable
distribution/supply network operator if necessary, that the equipment should be connected only to a supply with,
Short-circuit power Ssc 1150 kW
Service current capacity 100A per phase
The equipment complies with IEC/EN 61000-3-11 and IEC/EN 61000-3-12. Please liaise with supply authority to
ensure that the above items at the interface point are sufficient for the installation of the equipment.
2
), CU-5E34***
2
) 60245 IEC 57 type
2
flexible
4. Connect the power supply cord and
connection cable between indoor unit and
outdoor unit according to the diagram as
shown.
49