Smoke Control Areas and you can contact them for details of Clean Air Act requirements. The HWAM 4300 stoves detailed below have been recommended as suitable for use in smoke control areas when burning wood logs. The appliance has been fitted with a modified secondary air control to prevent closure of the air inlet below 25 %.
Congratulations on your new wood-burning stove complete with a HWAM SmartControl ® We are pleased that you have chosen a HWAM woodburning stove and confident that it will give you much pleasure. The HWAM SmartControl is a digital control of the combustion in your new wood-burning stove. The ®...
In general To ensure optimum operation and safety, we recommend that the installation should be carried out by an authorised HWAM retailer or a fitter recommended by the retailer. For an overview of HWAM retailers, visit www.hwam.com under “Retailer locations”.
Page 10
The chimney and flue duct must be of flue class T400 and be CE marked. Furthermore, it must have obtained the classification of G in soot fire testing. The required distance to combustible material must be complied with in accordance with the brand label. Ask your HWAM retailer for further information.
Page 11
• Built-in pipe sleeve (12). Fits smoke flue. • Wall rosette (13). Covers disruption to wall around pipe sleeve. • Joint (14). Sealed with packing material. • Smoke outlets (15) of the HWAM stove. • Smoke flue regulating damper (16). • Soot door (17).
If the chimney is too tall to be cleaned from above, it must be equipped with a soot door. In case of a chimney fire and overheating, the HWAM SmartControl will enter a security mode and ®...
Page 13
Place 2 firelighters between the top layer of kindling. Light up the fire-lighters and close the door. Select the desired room temperature level. As soon as the door is opened the HWAM SmartControl is activated. If lighting up does not occur ®...
Page 14
The HWAM SmartControl ® ® will signal that a restoking is due at the flue gas temperature of 180° C, and at 100° C the HWAM ® SmartControl will enter standby mode and all dampers will close.
® combustion. A good combustion is achieved when the fire gets the right amount of oxygen supply at the right time and place in the combustion chamber. The HWAM SmartControl allows for variations ®...
Page 16
kind of cleaner, as this will damage the lacquer. Once a year, the stove should be thoroughly serviced. The combustion chamber should be cleared of ashes and soot. The hinges and the closing hook must be greased with liquid copper fat spray (heat-resistant up to 1100 °C), (drawing H).
Guarantee The guarantee does not cover damage due to insufficient maintenance! Maintenance Alarms If a maintenance alarm goes off, you can continue using the wood-burning stove, but contact your retailer as soon as possible. Your stove could be affected by impure combustion. peraTional problemS Blackened glass •...
• Always dispose of items in a way that is as sustainable as possible and that is in line with the current environmental protection, reprocessing/recycling and disposal technology HWAM A/S • Nydamsvej 53 • DK-8362 Hørning Page 19 of 20 pages...
Need help?
Do you have a question about the 4340 and is the answer not in the manual?
Questions and answers