Twisted Pair Test Settings

Table 1 describes the settings that apply to twisted pair
cabling tests.
Setting
SETUP >
Select a cable type appropriate for the type you will test. The cable types are organized by type and
Twisted Pair >
manufacturer.
Cable Type
SETUP >
Select the appropriate test limit for the job.
Twisted Pair >
Test Limit
SETUP >
Nominal velocity of propagation, which is used with the measured propagation delay to determine
Twisted Pair >
cable length. The default value defined by the selected cable type represents the typical NVP for that
NVP
cable type. You may enter a different value if necessary. To determine the actual value, change the NVP
until the measured length matches the known length of a cable. Use a cable at least 15 m (50 ft) long.
The recommended length is 30 m (100 ft).
Increasing the NVP increases measured length.
To access the settings, turn the rotary switch to SETUP,
use
Table 1. Twisted Pair Test Settings
Description
D
to highlight Twisted Pair; then press
Twisted Pair Test Settings
H
.
-continued-
19