Other options on the Admin page are:
Device Nickname: Give your device a unique nickname to make it easier when viewing multiple devices.
Enable Emergency Shutdown: This option controls the safety relay on the thermostat. If the user is remotely
viewing and notices a problem this feature can be activated which will trigger the safety relay and cut power to
any outlets on the device.
Reset Device High / Low and PowerReset Tracking: This will clear all high / low data and also set the power
tracking option back to zero.
Enable Status Upload to herpstat.com:
Enabling this feature will allow the Herpstat to upload its status and charts to the herpstat.com website for
viewing. To access your status through our site navigate your device web browser to
http://www.herpstat.com/spyderweb
Log into our site using your email address that was entered in the Admin and your Admin Password.

Email Setup:

Note: The email address must be no longer than 39 characters.
If you completed the setup wizard and need to change your email info check the box next to CHANGE SENDTO
EMAIL ADDRESS and click Submit.
Enter your personal email address where you would like to receive alerts in the SendTo Email Address field and
click Submit.
Click the green link labeled CLICK HERE TO SEND THE VERIFICATION EMAIL.
The unit will then try to connect to our email service and send an email to you. The display of the Herpstat
device will indicate that it is sending the email. If it was successful you will hear a double beep. If it fails you
will hear a long beep and you will need to check your settings. Give it a minute and see if you receive a new
email. DO NOT HIT YOUR BROWSERS BACK BUTTON during this process. Check your email through your email
app or through another browser window. If you don't immediately see the test email check your spam folders.
Take the code from the email and enter it in the EMAIL VERIFICATION CODE and then click Submit.
If successful the additional email options will become available and you can now setup the device to send email
alerts.
Scheduled Email Interval: This setting determines how often the Herpstat will send your status email.
Enable Emergency Email: This option will trigger an email during alerts such as a probe error, high / low
temperature alarms, and device resets.
Enable Numbered Emails: This option will add an ID number to the subject line of all emails. Some services
like gmail will alter the formatting of an email that looks similar to a previous one. While you typically can read
the data the change in format can be distracting. Adding the ID number typically gets past this and allow the
email to look proper.