Connecting To The 10Base-T (Aj71E71N3-T, A1Sj71E71N3-T); Connecting To The 10Base5 (Aj71E71N-B5, A1Sj71E71N-B5); Connecting To The 10Base2 (Aj71E71N-B2, A1Sj71E71N-B2) - Mitsubishi MELSEC A Series User Manual

Ethernet interface module
Hide thumbs Also See for MELSEC A Series:
Table of Contents

Advertisement

5.1 Connecting to the 10BASE-T
(AJ71E71N3-T, A1SJ71E71N3-T)
For AJ71E71N3-T
5.2 Connecting to the 10BASE5
(AJ71E71N-B5, A1SJ71E71N-B5)
For AJ71E71N-B5
*1
Connect the AUI cable while the power to the module mounting station is
turned off.
*2
Use a transceiver with a function that is generally called SQETEST or heart
beat (a transceiver function that emits signals to notify whether the
transceiver is operating normally at the end of communication).
5.3 Connecting to the 10BASE2
(AJ71E71N-B2, A1SJ71E71N-B2)
For AJ71E71N-B2
Supply power
for transceiver
AUI cable
A
B
Retainer
[2]
[1]
12
<Connection procedure>
1) Connect the twisted pair cable and the
hub.
2) Connect the twisted pair cable to the E71.
<Connection procedure> (*1)
1) Slide the retainer toward the direction A
as shown in the figure.
2) Push in the AUI cable connector all the
way.
3) Slide the retainer toward the direction B
as shown in the figure.
4) Confirm that the AUI cable is locked.
5) Supply power to the transceiver (*2).
(Refer to *2 in Chapter 2)
<Connection procedure> (*2)
1) Push in the connector by aligning the
groove [1] and tab [2] as shown in the
figure.
2) While pushing in the connector, rotate it
clockwise by a 1/4 turn.
3) Turn until the connector locks.
4) Confirm that the connector is locked.