Setting the CO₂ content
Condition: The CO₂ content must be adjusted
Remove the sticker.
Remove the covering cap (1).
Turn the screw (2) to set the CO₂ content (value with
front casing removed).
To increase the CO₂ content: Turn anti-clockwise
To decrease the CO₂ content: Turn clockwise
Note
For natural gas only: Only perform the adjust-
ment in small increments of a 1/8 turn and
wait approx. one minute after each adjust-
ment until the value stabilises.
For liquefied petroleum gas only: Only per-
form the adjustment in extremely small incre-
ments (approx. 1/16 turn), and wait approx.
one minute after each adjustment until the
value stabilises.
Compare the measured value with the corresponding
value in the table.
Setting the CO₂ con-
tent
CO₂ at full load
Set for Wobbe index
W₀
O₂ at full load
CO at full load
CO/CO₂
36
1
2
Removed
Fitted front
front casing
casing
Natural gas H
Natural gas H
9.0 ±0.2 vol. %
9.2 ±0.2 vol. %
14.09 kW⋅h/m³
14.09 kW⋅h/m³
4.5 ±1.8 vol. %
≤ 250 ppm
≤ 250 ppm
≤ 0.0028
≤ 0.0028
Setting the CO₂ con-
tent
CO₂ at full load
Set for Wobbe index
W₀
O₂ at full load
CO at full load
CO/CO₂
If the setting is not in the specified adjustment range,
you must not start up the product.
Contact customer service.
Check whether the air-quality requirements with regard
to carbon monoxide are fulfilled.
Refit the covering cap.
Install the front panel.
12.7

Removing the compact thermal module

Note
The compact thermal module consists of four
main components:
– Speed-regulated fan,
– Gas-air mixture unit,
– Gas supply (mixture pipe) with burner flange,
– Premix burner.
Danger!
Risk of death and risk of material damage
caused by hot flue gas.
The seal, insulating mat and self-locking nuts
on the burner flange must not be damaged.
Otherwise, hot flue gases may escape and
cause personal injury and material damage.
Replace the seal each time you open the
burner flange.
Replace the self-locking nuts on the
burner flange each time you open the
burner flange.
If the insulating mat on the burner flange
or on the back wall of the heat exchanger
shows signs of damage, replace the insu-
lating mat.
1.
Switch off the product using the on/off button.
2.
Close the gas stopcock.
3.
Remove the front casing.
4.
Tilt the electronics box forwards.
Installation and maintenance instructions ecoTEC sustain 0020253094_05
Removed
Fitted front
front casing
casing
Liquefied pet-
Liquefied pet-
roleum gas P
roleum gas P
10.1 ±0.2 vol.
10.3 ±0.2 vol.
%
%
21.34 kW⋅h/m³
21.34 kW⋅h/m³
5.1 ±0.8 vol. %
≤ 250 ppm
≤ 250 ppm
≤ 0.0025
≤ 0.0025