Setting The Domestic Hot Water Temperature; 11 Handing Over To The End User - Vaillant ecoTEC sustain 24 Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

1
Regulate the pressure using the adjusting screw (1).
Pres-
Position of the
sure
adjusting screw
in MPa
(mbar)
Right-hand stop
0.035
(turned all the
(350)
way down)
Mid-position (six
0.025
anti-clockwise
(250)
rotations)
Five further anti-
clockwise rota-
0.017
tions starting from
(170)
the mid-position
Install the front casing.
10.7

Setting the domestic hot water temperature

Danger!
Risk of death from legionella.
Legionella multiply at temperatures below
60 °C.
Ensure that the end user is familiar with
all of the Anti-legionella measures in order
to comply with the applicable regulations
regarding legionella prevention.
1.
Set the domestic hot water temperature.
Condition: Water hardness: > 3.57 mol/m³
Domestic hot water temperature: ≤ 50 ℃
2.
Descale the water as required.
3.
Observe the applicable regulations regarding legionella
prevention.
34
Notes/application
If the radiators do not heat
up sufficiently at the default
setting. In this case, you
must set the pump to the
maximum speed.
Default setting
If noises are produced in
the radiators or radiator
valves
Installation and maintenance instructions ecoTEC sustain 0020253094_05

11 Handing over to the end user

At the time of commissioning complete all relevant sec-
tions of the Benchmark commissioning checklist, located
at the rear of this document.
For IE: Complete a "Declaration of Conformity" to indicate
compliance to I.S. 813. An example of this is given in the
current edition of I.S. 813.
When you have finished the installation, affix the en-
closed sticker (which requests that the user reads the
instructions) to the front of the product in the end user's
language.
Draw attention, to the current issue of the Gas Safety
(Installation and Use) Regulations, Section 35, which
imposes a duty of care on all persons who let out any
property containing a gas appliance in the UK.
Explain to the end user how the safety devices work and
where they are located.
Inform the end user how to handle the product.
In particular, draw attention to the safety warnings that
the end user must follow.
Inform the end user that they must have the product
maintained in accordance with the specified intervals.
Pass all of the instructions and documentation for the
product to the end user for safe-keeping.
Inform the end user about measures taken to ensure
the supply of combustion air and flue gas guiding, and
instruct the operator that he must not make any changes.
Inform the end user that they must not store or use explo-
sive or highly flammable substances (such as petrol, pa-
per or paint) in the installation room of the product.
Complete and sign off the Benchmark commissioning
check list.
Complete and sign off the guarantee documentation.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents