Connecting the cable
Two electronic cables must be connected to the outdoor unit.
The connection cord between indoor unit and outdoor unit.
The power cable between outdoor unit and auxiliary circuit breaker.
Specially for Russian and European market, before installation, the supply authority should be consulted to
determine the supply system impendance to ensure compliance.
CAUTION
D uring the unit installation make first refrigerant connections and then electrical connections.
If unit is uninstalled first disconnect electrical cables, then refrigerant connections.
C onnect the air conditioner to grounding system before performing the electrical connection.
Example of Air Conditioner System
When using ELB for 1 phase
1Φ
When using ELB for 3 phase
3Φ
If an outdoor unit is installed in a place in danger of an electric leak or submergence, you must install the ELB.
Power Cable Specifications
Type of outdoor unit
A
B
The power cable is not supplied with air conditioner.
For power cable, use the grade H07RN-F or H05RN-F materials.
10
E-
Outdoor Unit
Power cable
Grounding
Outdoor Unit
3Φ
Grounding
Outdoor
Power supply
1Φ, 220-240V~, 50Hz
DC30ETTX
1Φ, 220-240V~, 50Hz
DC36ETTX
DC42ETTX
1Φ, 220-240V~, 50Hz
3Φ, 380-415V~, 50Hz
DC48GTTX
DC60GTTX
3Φ, 380-415V~, 50Hz
DC72GTTX
Communication cable
Indoor Unit
Communication cable
Indoor Unit
Power cable
power cable
MAX. LENGTH
mm²,wires
m
2.5/2
< 10m
3.5/2
< 10m
3.5/2
< 10m
2.5/3
< 10m
3.0/3
< 10m
Power cable
Communication cable
Type GL
MCCB
A
A
20
20
20
25
20
25
20
20
20
20