5
COAXIAL RETROREFLECTIVE TYPE LS-H901□
● In principle, the coaxial retroreflective type (LS-H901□) may be unable to detect a
mirror object or an object which easily diffuses the receiving light at a short sens-
ing distance since the polarized light becomes unstable.
In this case, take the following measures.
<Measures>
• Lower the receiving light sensitivity with the light-receiving sensitivity function of
the amplifier.
• Change the response time.
• Make the distance between the sensor head and the sensing object farther.
● The receiving light sensitivity may change depending on the surface condition of
the reflector. When a threshold value is set with the applicable amplifier LS-500
series, sufficient margin should be taken into account.
6
WIRE CONNECTION
● The cable of sensor head can be shortened to your desired length. However, it
cannot be extended.
<Connector for amplifier connection>
Wire inlet
Strip gauge
Wire connecting procedure
1. Process the core length to 7 to 8mm in ac-
cordance with "STRIP GAUGE" indicated on
the side of this unit, and twist the core sev-
eral times.
When using shielded wires, twist the wire un-
til obtaining the diameter of ø1.2mm or less.
2. Use a flathead screwdriver (Blade width:
2 mm or less) to push the operating lever
(white) located at the operating area until it is
locked.
Blade width
2mm or less
3. Insert the wire to the innermost of the wire
inlet. Check that the shielded wire is properly
inserted into the wire inlet as well as that the
core end has passed through the wire con-
nection area as shown in the right figure.
Terminal No.
1
Purple
1
Thru-beam type · Emitter: Gray
2
White
2
Coaxial retroreflective type, Diffuse reflective type: Black (with gray stripe)
3
3
Shield
4
4
Shield
5
Thru-beam type · Receiver: Black
5
Black
6
Coaxial retroreflective type, Diffuse reflective type: Black
6
Pink
4. Place the head of a flathead screw-driver un-
derneath the operating lever (white) through
the releasing slot, and lift the screwdriver
head. If you hear a snap, the operating lever
(white) is returned and the wire is fixed.
5. Lightly pull the wire to ensure that wire is not
loose.
Releasing procedure
1. Use a flat-head screwdriver (Blade width:
2mm or less) to push the operating lever
(white) located at the wire inlet and remove
the wire.
Wire inlet
Operating lever (white)
Releasing slot
Release lever
Operating lever
(white)
Core length
7 to 8mm
Flathead
2. Push
screwdriver
Operating lever
(white)
Shielded wire
Wire connection area
Core end
Connecting cable
4. Lift
Operating lever
(white)
Releasing slot
Flathead
1. Remove
screwdriver
Operating lever
(white)
7
SPECIFICATIONS
Type
Model No. (Note 2)
Applicable amplifier
STD mode
LONG mode
Sensing
U-LG mode
range
HYPR mode
(Note 3)
H-SP mode
FAST mode
Ambient temperature
Ambient humidity
Emitting element
Material
Cable
Weight
Accessories
Notes: 1) The model No. of retroreflective type sensor with the suffix "-Y" is the sensor without the RF-330 reflector.
Arrange the reflector separately.
(e.g.) LS-H901-Y
2) The model No. with suffix "-C5" stands for the 5m cable length type.
(e.g.) LS-H101-C5
3) Configure the mode settings in the applicable amplifier LS-500 series.
8
CAUTIONS
This product has been designed to meet the specifications when it is used along
with the optional exclusive amplifier. If an amplifier other than the exclusive ampli-
fier is used, not only the specifications may not be met, but it may also be a cause
for malfunction or break down. Hence, please ensure to use this product along with
the optional exclusive amplifier.
Wire
● This product has been developed / produced for industrial use only.
● Always use the sensor with the connector to be joined to the amplifier.
● Make sure that the power is off while wiring to the amplifier.
● In case noise generating equipment (switching regulator, inverter motor etc.) is
used in the vicinity of this product, connect the frame ground (F.G.) terminal of the
equipment to an actual ground.
● If power is supplied from a commercial switching regulator, ensure that the frame
ground (F.G.) terminal of the power supply is connected to an actual ground.
● Do not use the sensor during the initial transient time (0.5 sec.) just after the
power supply is switched on.
● Do not use the sensor during the initial transient time (0.5 sec.) just after the
power supply is switched on.
● Do not run the wires together with high-voltage lines or power lines or put them in
the same raceway. This can cause malfunction due to induction.
● When using the thru-beam type LS-H101 or LS-H102, do not set the receiving
light sensitivity (gctL) of the applicable LS-500 series amplifier to level 2 or less.
3. Insert
This is because there is a possibility of sensing becoming unstable.
Wire
● Take care that the sensor head is not directly exposed to fluorescent lamp from a
inlet
rapid-starter lamp or a high frequency lighting device, as it may affect the sensing
performance.
● The sensor head cable cannot be extended.
● Make sure that stress is not applied to the sensor head cable joint.
● This sensor is suitable for indoor use only.
● Do not allow any water, oil fingerprints, etc., which may refract light, or dust, dirt,
etc., which may block light, to stick to the emitting/receiving surfaces of the sensor
head. In case they are present, wipe them with a clean, soft cloth or lens paper.
● Do not use the sensor in vaporous, dusty or corrosive gas atmospheres.
● Take care that the sensor does not come in contact with water, oil, grease or or-
ganic solvents, such as, thinner, etc.
● Make sure that the power is off while cleaning the emitting / receiving windows of
the sensor head.
● When carrying out teaching using the applicable LS-500 series amplifier, set
a threshold which provides a reasonable margin. If there is insufficient margin,
sensing will become unstable.
● This device is using a laser which has high directional quality. Therefore the beam
possibly be out of alignment by the mounting condition of this device or distortion
of housing etc. Make sure to adjust the beam axe alignment before use.
● Since vibration, impact and ambient temperature affect the sensitivity, the installa-
tion and the sensitivity adjustment must have some margins.
http://panasonic.net/id/pidsx/global
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
For sales network, please visit our website.
PRINTED IN JAPAN
Thru-beam type
Coaxial retroreflec-
tive type (Note 1)
Cylindrical
Small
LS-H101
LS-H102
LS-H901
LS-500 series
0.01 to 1m
0.01 to 1.5m
0.01 to 2m
0 to 1m
0 to 1m
0.01 to 2.5m
0.01 to 1m
0.01 to 1m
-10 to +55°C (No dew condensation or icing allowed), Storage: -20 to +70°C
35 to 85% RH, Storage: 35 to 85% RH
Red semiconductor laser Class 1 (IEC / JIS / GB standard)
(Max. output: 2mW or less, Peak emission wavelength: 660nm)
Enclosure: Stainless steel
Enclosure:
Enclosure: Polybutylene terephthalate
Front cover:
Polybutylene terephthalate
Front cover: Glass
Polycarbonate
Front cover: Acylic
2
2
0.11mm
(shielded wire: 0.16mm
) shielded cable, 2m long
Each emitter and receiver: Approx. 50g
RF-330 (Reflector):
M6 nut: 4 pcs.
MS-EXL2-2
1 pc.
Toothed lock washer
(Metal plate): 2 pcs.
MS-LS-1
: 2 pcs.
(Metal plate): 1 pc.
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
Diffuse reflective
type
LS-H201
0 to 300mm
0 to 450mm
0 to 600mm
0 to 750mm
0 to 150mm
0 to 200mm
Approx. 50g
MS-LS-1
(Metal plate): 1 pc.

Advertisement

loading

This manual is also suitable for:

Ls-h101Ls-h102Ls-h901Ls-h201