8-3. FAULT DIAGNOSIS AND TROUBLESHOOTING
CAUTION
1. Be careful of electric shock if disconnecting parts while troubleshooting.
2. First of all, check the connection of each electrical terminal with the wiring diagram.
3. If you replace the MAIN PWB ASSEMBLY, reinsert the connectors correctly.
LGE Internal Use Only
NO POWER
Is the supplied voltage 120V AC?
Is the voltage between the 2 FILTER ASSEMBLY
connectors 120V AC?
Is the LED (1) on?
Are the connectors (2) on the PWB loose?
Is wire of the DISPLAY PWB ASSEMBLY
broken?
Replace DISPLAY PWB ASSEMBLY
or repair wire.
20
Copyright © 2016 ~ 2017 LG Electronics Inc. All rights
reserved. Only training and service purposes.
Check the fuse or reset
the circuit breaker.
Replace the FILTER
ASSEMBLY (CIRC).
Replace MAIN PWB
ASSEMBLY.
Reconnect.
Replace the MAIN PWB