NTRODUCTION
The TagTemp-NFC is an electronic temperature logger. The sensor
measures this physical quantity and the values are stored in memory.
These data are collected by a smartphone equipped with an NFC
interface (not included).
The LogChart-NFC software enables to set up the equipment
operation mode. It is also used for viewing acquisitions. Other
parameters such as end of measurements, logging interval, etc., are
easily defined through the LogChart-NFC software.
The LogChart-NFC application is targeted to ANDROID™ platform
and must be downloaded from Google Play Store.
2 MECHANICAL INSTALATION
The TagTemp-NFC can be fixed in two ways: by using of screws or
double-sided tape.
For mounting with screws, you should detach the front film of the
equipment carefully, exposing two through holes where TagTemp-
NFC may be screwed, as shown in Fig.1. They should be used M3
flathead screws. When finished, you should stick extra film that
comes with the product to cover again the front of the device.
The other way is to use a double-sided adhesive tape on the back of
the equipment, avoiding placing it above the identification label.
In both cases, the temperature sensor should be placed near the
place where you want to measure the temperature.
Fig. 01 - Mounting holes on the TagTemp-NFC
NOVUS AUTOMATION
3
TECHNICAL DATA
Measure Range
Temperature: -40.0 °C to 70.0 °C.
± 0.5 ºC @ 25 ºC.
± 1 °C max. over the full measuring
range.
Accuracy
Note: A measurement error can be
ruled out using the OFFSET parameter
in the LogChart-NFC software.
Measurement
Temperature: 0,1 °C / 0,1 ° F.
Resolutions
Memory capacity
Up to 4020 logs.
5 minutes min.
Measurement Interval
2 hours max.
2 x 3.0 V lithium battery, built-in, non-
Supply
replaceable.
• Above 300 days – 5-minute logging
interval.
Estimated battery
autonomy
• Above 400 days – 30-minute
logging interval.
Operating temperature
From -10 °C to 70 °C
Dimensions (L x W x H) Main body: 65 x 44 x 8 mm.
RF Interface
ISO 15693 (NFC-V) compatible.
Logger-Smartphone
Approx. 20 seconds (depends on the
data transfer time
smartphone processing speed).
Android version: 4.0 or above.
LogChart-NFC
software
Languages: Portuguese and English.
USB to NFC converter interface
PC Interface
(optional), compatible with LogChart-II
for Windows ®.
Material
Polyamide
All electronics are protected by the
Protection
housing.
1/9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TagTemp-NFC and is the answer not in the manual?

Questions and answers

Summary of Contents for Novus TagTemp-NFC

  • Page 1 Memory capacity Up to 4020 logs. 2 MECHANICAL INSTALATION 5 minutes min. The TagTemp-NFC can be fixed in two ways: by using of screws or Measurement Interval 2 hours max. double-sided tape. For mounting with screws, you should detach the front film of the 2 x 3.0 V lithium battery, built-in, non-...
  • Page 2: Operation

    TagTemp-NFC button (when configured this option). A digital input is available on some models of TagTemp-NFC. It allows If you pressed the TagTemp-NFC button to stop the recording data, to record state changes, i.e., records the moment when the digital input and after a while, you pressed again to resume, the recording will changed from OFF (logic "0") to ON (logic "1") and vice-versa.
  • Page 3: Installing The Application

    NFC. Log Interval: Displays the value of the interval between acquisitions configured. Loggings: Number of records stored by the TagTemp-NFC, to the maximum of 4020 records. Fig. 02 – NFC Communication Logging State: Displays whether or not the device is recording 5.2 Operation of the App...
  • Page 4: Device Configuration

    Last Occurrence: Time and value of the last occurrence below the lower limit of range. Total logs within Occurrences: Number of acquisitions for events below the lower limit of range. Average Temperature within Occurrences: Average value of the temperatures below the minimum range. NOVUS AUTOMATION...
  • Page 5 Fig. 10 – Digital Input Events Screen Fig. 14 – Message for High Excursions for "No occurrences" Fig. 11 – High Excursions Screen Fig. 15 – Message for Low Excursions for "No occurrences" Fig. 12 – Low Excursions Screen NOVUS AUTOMATION...
  • Page 6: Preference Settings

    5.2.4.1 Full Screen Chart Export configuration (.CFG): Share a CFG extension file with the settings of the TagTemp-NFC. By clicking the icon in the upper right of the "Data Chart" Export digital inputs (.CSV): Share a CSV format file with all screen, the enlarged graph is displayed.
  • Page 7: Configuring The Equipment

    After checking the proper functioning of the selected port, it the available memory. will be marked. When the TagTemp-NFC is over the NFC reader and • “S” button: acquisitions stops when the "S" button is it is recognized, will enable the icons shown below.
  • Page 8: Offloading Data

    Stop Button The graphic curves can be vertically dragged with a right-click and dragging the mouse up and down. The stop button is enable with a fully configured device. Fig. 25 - Visualizing Data screen NOVUS AUTOMATION...
  • Page 9: Exporting Data

    "acquisitions" for display purposes. 6.6.3 General information table This window shows some information about the equipment whose data were just read and its configuration. The screen can be displayed by pressing the icon Parameter Viewing: Fig. 27 – General information NOVUS AUTOMATION...

This manual is also suitable for:

88137020008813700000

Table of Contents