Manual Cable transducer GCA3/5/8/12/20 with CANopen Inclinometer Integrated (option) GCA3/5 (C50) Firmware Version 3.87 and up GCA3/5 (C60/C80) Firmware Version 1.23 and up GCA8/12/20 (C50) Firmware Version 3.07 and up Baumer – Sensor Systems s.r.l. Via Caduti del lavoro 9...
PDO mapping .............................. 13 6.4.1 Mappable objects ............................13 6.4.2 Default mapping of absolute encoder redundant with cable-pull ..............13 Timing ................................14 Exceptions of accurate calculation of process data ..................14 Baumer – Sensor Systems s.r.l. Baumer_GCA3-5-8-12-20_CANopen_MA_EN_Rev10.docx 2/23 03.12.2019 Chiari (Bs), Italy...
Where working with consumers which have high interference emissions, make available a separate power supply for the cable transducer. Unused outputs must not be connected. Failure to observe these instructions can result in malfunctions, material damage or personal injury. Baumer – Sensor Systems s.r.l. Baumer_GCA3-5-8-12-20_CANopen_MA_EN_Rev10.docx 4/23 03.12.2019 Chiari (Bs), Italy...
The step size for all position objects can be adapted in the object 0x6005. The basic unit is nanometer Example 1: A position step setting of 1’000’000 nm/step means that the position output unit is 1mm. Baumer – Sensor Systems s.r.l. Baumer_GCA3-5-8-12-20_CANopen_MA_EN_Rev10.docx 6/23 03.12.2019...
Note: ID can be 0 for broadcast initialization After a power-on or NMT reset, the device will send a Boot up message. COB ID Byte 0 700h + node ID Baumer – Sensor Systems s.r.l. Baumer_GCA3-5-8-12-20_CANopen_MA_EN_Rev10.docx 7/23 03.12.2019 Chiari (Bs), Italy...
Note: Values above 7 are not accepted and the existing setting remains valid. After setting the new entries a SAVE command (see par. “How to save data”) followed by a turnoff and on. Baumer – Sensor Systems s.r.l. Baumer_GCA3-5-8-12-20_CANopen_MA_EN_Rev10.docx 8/23 03.12.2019...
How to set the length zero 5.3.6 Send the SDO message to set the zero of channel 1 COB-ID 0x600 + ID 0x23 0x10 0x60 0x01 0x00 0x00 0x00 0x00 Baumer – Sensor Systems s.r.l. Baumer_GCA3-5-8-12-20_CANopen_MA_EN_Rev10.docx 9/23 03.12.2019 Chiari (Bs), Italy...
C is a differential slope offset and t = time when accessing object a preset object The 16bit and 32bit values are hardwired internally (i.e. changing the differential offset at 6814h changes the differential offset at 6914h) Baumer – Sensor Systems s.r.l. Baumer_GCA3-5-8-12-20_CANopen_MA_EN_Rev10.docx 10/23 03.12.2019...
0x00 5.3.10 Angle Digital Filter Configuration (2603h) For GCA3/5 (C60/C80) the IIR coefficient is expressed in tenths of hertz. E.g.: Fc = 3 Hz -> 30d(0x1E). The value can be selected in a range from 0 to 300(30Hz). While for all the other type of GCA, The IIR coefficient is expressed in % (lower values->more filtering).
Considering a resolution of 0.1°: P0 = 0x84, P1 = 0x03 It means P = 0x00000384 (900 decimal) = 90° The channel ’b ’ is represented in a similar way. Baumer – Sensor Systems s.r.l. Baumer_GCA3-5-8-12-20_CANopen_MA_EN_Rev10.docx 12/23 03.12.2019 Chiari (Bs), Italy...
Exceptions of accurate calculation of process data The following operations could interrupt the accurate calculation of process data such as position, speed, warnings and alarms: Non-volatile operations Changing the scaling parameters Baumer – Sensor Systems s.r.l. Baumer_GCA3-5-8-12-20_CANopen_MA_EN_Rev10.docx 14/23 03.12.2019 Chiari (Bs), Italy...
In other words, the sensor is in the pre-operational mode (7Fh = 127). COB-ID The COB-ID for the heartbeat message is 700h + node ID. Timing The minimal cycle time for heartbeat messages is 10 ms. Baumer – Sensor Systems s.r.l. Baumer_GCA3-5-8-12-20_CANopen_MA_EN_Rev10.docx 16/23 03.12.2019 Chiari (Bs), Italy...
Inquire identity serial number Inquire identity node ID LSS address The needed value for LSS addressing as serial number is printed on a label on the encoder housing. Baumer – Sensor Systems s.r.l. Baumer_GCA3-5-8-12-20_CANopen_MA_EN_Rev10.docx 17/23 03.12.2019 Chiari (Bs), Italy...
Page 20
5=100 kBit/s 6=50 kBit/s 7=20 kBit/s The baudrate is activated after a reset or power-on (if parameter is saved to non volatile memory) 0x3001 Node Id U8, rw 0x04 0x01...0x7F Baumer – Sensor Systems s.r.l. Baumer_GCA3-5-8-12-20_CANopen_MA_EN_Rev10.docx 20/23 03.12.2019 Chiari (Bs), Italy...
0x64 This object shall indicate the resolution of Slope long16 (object 7010h) and Slope lateral16 (object 7020h) objects based on 0,001°. This resolution is also valid for the 32-bit value Baumer – Sensor Systems s.r.l. Baumer_GCA3-5-8-12-20_CANopen_MA_EN_Rev10.docx 21/23 03.12.2019 Chiari (Bs), Italy...
Page 22
Slope long16 preset value (object 7012h) and Slope long16 offset (object 7013h). The value shall be given in degree (angle) with the resolution given in object 7000h. only if the version of GCA (C50); Baumer – Sensor Systems s.r.l. Baumer_GCA3-5-8-12-20_CANopen_MA_EN_Rev10.docx 22/23 03.12.2019...
Signal Description White Ground referred to +Vs Brown Supply voltage Grey CAN_GND CAN bus ground Green CAN_H CAN bus signal (dominant High) Yellow CAN_L CAN bus signal (dominant Low) Baumer – Sensor Systems s.r.l. Baumer_GCA3-5-8-12-20_CANopen_MA_EN_Rev10.docx 23/23 03.12.2019 Chiari (Bs), Italy...