The present manual was compiled with utmost care, errors and omissions reserved. For this reason Baumer rejects any liability for the information compiled in the present manual. Baumer nor the author will accept any liability for direct or indirect damages resulting from the use of the present information.
This manual is intended as a supplement to already existing documentation (catalogues, data sheets and assembly instructions). The manual must be read without fail before initial commissioning of the equipment. Baumer_GCAxx_CANopen_EN_Rev0000.0000_Index0005_MNL.docx Baumer Sensors Srl 18.04.2024 5/28 Chiari (BS), Italy...
2 TPDOs (according to CiA 301/CiA 406/ CiA 410) 1 Emergency Producer (according to CiA 301/CiA 406/ CiA 410) 1 Heartbeat Producer (according to CiA 301) 1 LSS Client (according to CiA 305) Baumer_GCAxx_CANopen_EN_Rev0000.0000_Index0005_MNL.docx Baumer Sensors Srl 18.04.2024 7/28 Chiari (BS), Italy...
In a sensor with redundant design (2-sensing), there are two primary sensors that are read by a single node with a single node ID connected to the network. The values of each primary sensor read by the node are written to separate objects. Baumer_GCAxx_CANopen_EN_Rev0000.0000_Index0005_MNL.docx Baumer Sensors Srl 18.04.2024 8/28...
0x01 Note: ID can be 0 for broadcast initialization After a power-on or NMT reset, the device will send a Boot up message. COB ID Byte 0 700h + node ID Baumer_GCAxx_CANopen_EN_Rev0000.0000_Index0005_MNL.docx Baumer Sensors Srl 18.04.2024 9/28 Chiari (BS), Italy...
I.e: if it’s necessary to have the measure expressed in 10 mm, the value to write must be 10’000’000 nm, to obtain instead a resolution of 0.1 mm, the value to write will be 100’000 nm Baumer_GCAxx_CANopen_EN_Rev0000.0000_Index0005_MNL.docx Baumer Sensors Srl 18.04.2024 11/28...
The operating parameters are applied for the according slope (i.e. 6811h operating parameter influences 6810h slope). The 16-bit and 32-bit values are hardwired internally (i.e. changing the operating parameter at 6811h changes the operating parameter at 6911h). Baumer_GCAxx_CANopen_EN_Rev0000.0000_Index0005_MNL.docx Baumer Sensors Srl 18.04.2024 12/28 Chiari (BS), Italy...
The Length Filter can be adjusted through the object 2103h. The IIR coefficient is expressed in %. The value can be selected in a range from 0 to 100 The default coefficient is 20. Baumer_GCAxx_CANopen_EN_Rev0000.0000_Index0005_MNL.docx Baumer Sensors Srl 18.04.2024 13/28 Chiari (BS), Italy...
R is the actual rotation value in degrees or tenths of degrees (depending on the resolution settings). Interpretation example Considering a resolution of 0.1°: P0 = 0x84, P1 = 0x03 It means P = 0x00000384 (900 decimal) = 90°. PDO mapping The sensor supports dynamic mapping. Baumer_GCAxx_CANopen_EN_Rev0000.0000_Index0005_MNL.docx Baumer Sensors Srl 18.04.2024 14/28 Chiari (BS), Italy...
Where OBJ_NBR increase starting from 1 to maximum 8 every obj associated mapped Where TOT_NBR is the Total number of mapped object Where SIZE is: 8h for 1 byte obj. 10h for 2 byte obj. 20h for 4 byte obj. Baumer_GCAxx_CANopen_EN_Rev0000.0000_Index0005_MNL.docx Baumer Sensors Srl 18.04.2024 15/28 Chiari (BS), Italy...
Exceptions of accurate calculation of process data The following operations could interrupt the accurate calculation of process data such as position, speed, warnings and alarms: Non-volatile operations Changing the scaling parameters Baumer_GCAxx_CANopen_EN_Rev0000.0000_Index0005_MNL.docx Baumer Sensors Srl 18.04.2024 16/28 Chiari (BS), Italy...
The following table indicates the values that can be set in the sub-index of the object. Value Description 0x00 Change to NMT state Pre-operational (only if currently in NMT state Operational) 0x01 No change of the NMT state 0x02 Change to NMT state Stopped Baumer_GCAxx_CANopen_EN_Rev0000.0000_Index0005_MNL.docx Baumer Sensors Srl 18.04.2024 18/28 Chiari (BS), Italy...
In other words, the sensor is in the pre-operational mode (7Fh = 127). COB-ID The COB-ID for the heartbeat message is 700h + node ID. Timing The minimal cycle time for heartbeat messages is 10 msec. Baumer_GCAxx_CANopen_EN_Rev0000.0000_Index0005_MNL.docx Baumer Sensors Srl 18.04.2024 19/28 Chiari (BS), Italy...
Selective switch mode The following procedure can be used to address a certain sensor in the bus system. 7E5h -> Vendor ID reserved 7E5h -> Product code reserved 7E5h -> Revision number reserved Baumer_GCAxx_CANopen_EN_Rev0000.0000_Index0005_MNL.docx Baumer Sensors Srl 18.04.2024 20/28 Chiari (BS), Italy...
Page 21
: After the delay, the sensor logs on with the new baud rate. Request vendor ID Requesting the vendor ID of a selected sensor 7E5h -> reserved 7E4h <- 32 bit vendor ID reserved Vendor ID : = 0x005F – GCA series products Baumer_GCAxx_CANopen_EN_Rev0000.0000_Index0005_MNL.docx Baumer Sensors Srl 18.04.2024 21/28 Chiari (BS), Italy...
Page 22
Revision number HIGH reserved 7E5h -> Serial number LOW reserved 7E5h -> Serial number HIGH reserved Each sensor with the relevant parameters logs on with the following message: 7E4h <- reserved Baumer_GCAxx_CANopen_EN_Rev0000.0000_Index0005_MNL.docx Baumer Sensors Srl 18.04.2024 22/28 Chiari (BS), Italy...
0x1017 0x0000 time producer heartbeat Numbers of 0x04 identity-options Vendor ID 0x005F GCA series products 0x1018 Product code As described in paragraph 3.1 Revision number 0x00000000 Serial number Depending by the SN of the product Error behavior 0x02 / 0x03...
Channel 2* from Zero, accordingly to the resolution) 0x14 for hall effect based sensors Length filter IIR coefficient expressed in % (lower values->more 0x2103 0x50 for strength filtering) potentiomet er based sensors Baumer_GCAxx_CANopen_EN_Rev0000.0000_Index0005_MNL.docx Baumer Sensors Srl 18.04.2024 24/28 Chiari (BS), Italy...
Page 25
6=50 kbits/s 7=20 kbits/s 8=10 kbits/s The baud rate is activated after a reset or power-on (if parameter is saved to non-volatile memory) 0x3001 Node ID 0x04 Node number 1…127 (0x01...0x7F) Baumer_GCAxx_CANopen_EN_Rev0000.0000_Index0005_MNL.docx Baumer Sensors Srl 18.04.2024 25/28 Chiari (BS), Italy...
Slope long16-bit = physically measured angle + operating 0x02 0x6811 Differential slope long16-bit offset + Slope long16-bit parameter** offset If scaling is disabled, the Slope long16-bit value shall be equal to the physical measured angle. Baumer_GCAxx_CANopen_EN_Rev0000.0000_Index0005_MNL.docx Baumer Sensors Srl 18.04.2024 26/28 Chiari (BS), Italy...
Page 27
This object shall shift the Slope long16-bit value (object 0x7014 long 16-bit offset 0x0000 7010h) independent of Slope long16-bit preset value Channel 2*** (object 7012h) and Slope long16-bit offset (object 7013h). Baumer_GCAxx_CANopen_EN_Rev0000.0000_Index0005_MNL.docx Baumer Sensors Srl 18.04.2024 27/28 Chiari (BS), Italy...
Page 28
**Note: The inclinometer objects 6800h...6914h and 6E11h exist for products with integrated inclinometer only. Note: The inclinometer objects 7010h...7114h and 7511h exist only for products with integrated inclinometer and redundant version (2- sensing). Baumer_GCAxx_CANopen_EN_Rev0000.0000_Index0005_MNL.docx Baumer Sensors Srl 18.04.2024 28/28 Chiari (BS), Italy...
Need help?