Flue

This appliance is designed to be run with Ø150mm stainless steel flue with Ø250mm
galvanised liner. Keep horizontal or inclined flue sections to a minimum, as
accumulation of ash will occur in these sections and access for cleaning needs to be
provided.
As the flues are provided by various manufacturers, the flue must be installed to
AS/NZS 2918:2001. Some councils have their own specific rule on the height of the
flue, but most follow Rule 4.5.6(b) and Schedule 6 and Section 4.9.1 of AS/NZS
2918:2001. Minimum clearances to combustible materials outlined in these and any
local regulations must be maintained.
It is the responsibility of the installer to ensure that the installation is compliant with
AS/NZS 2918 and all other relevant national codes and local body regulations.
Ecomax can supply a compliant flue kit that has been tested to AS/NZS 2918. A
schematic of this flue kit is on the following page.
If the ceiling contains insulation (such as batts) then an insulation barrier will be
required between the insulation and the flue liner.