REPLACING AN OUTPUT / SWITCH MODULE
Every controller is equipped with 1, 2 or 3 4-channel output
and switching modules. They can be either Low Voltage
Control or Direct Control modules.
Output/switch modules can be easily replaced for repair or
servicing. Turn off power before opening the controller.
When an output/switch module is replaced the new module
INTRODUCING THE PROLYFT AETOS RANGE
must be properly addressed with the dip-switches.
Addressing must be done before reconnecting the power
to the controller.
When Simplicity in Motion is the ultimate goal, there's always a next level to
On each output / switch module there are 6 dip-switches.
meet. ProLyft invites you to take that level further with a product range that is fit
Dip-switch 1 thru 4 represent the binary address setting of the
-
to meet the future
module.
Dip-switch 5 is to select DC or LV.
-
Get Ready for the Next Level
Dip-switch 6 is the terminator switch.
-
ProLyft AETOS is the brand new ProLyft hoist range. The AETOS range is fully
equipped to meet future demands in lifting equipment and offers clever features
Setting the address dip-switches:
and carefully engineered product attributes. The AETOS range comprises of a
With the front panel of the controller towards you the output /
standard 500kg and 1000kg hoist and will be expanded in the near future.
switch module on the right is no. 1, representing channel 1-4.
The Unique ProLyft Program
Module 1 (channel 1-4)
ProLyft sustains a unique service programme on its complete hoist range,
developed to offer maximum service and support for all hoist owners.
This program encompasses:
• Installed network of trained and certified Service Points
• Lifetime warranty
• Individual identification - easy web-enabled track and trace functions
• ProLyft Service database – automatic reminders for re-certification
• Test certificates worldwide available for owners of every hoist
Standard Features of the AETOS Range:
• Available in a 500kg and a 1000kg hoist body
• Fixed speed of 4m/min
• Red CEE form plug 16Amp 4pin and cable with strain relief
Module 2 (channel 5-8)
for power connection
• Yellow CEE form plug 16Amp 4pin and cable with strain relief
for low voltage control (optional)
• Equipped with limit switches on all hoists
• End limit switches are activated by chain stop for 100% repeatable accuracy
and easy of use
• External limit switches can be used for hoists used above a grid or false ceiling
• Multiple voltage motor
• Chain bags for 30mtr up to 80mtr available
• 5-pocket load wheel
• Zinc-plated load chain
• 100% sealed aluminium transmission house without oil plugs
• Standard swivel hook on hoist body and hoist chain
• IP 55 protection
Module 3 (channel 9-12)
Easily Adaptable:
• Covers 180 degree rotatable for motor-up use
• Easy mounting of optional second brake
• Brake shaft and electronics prepared for second brake
• Output shaft prepared for rotary limit switch or encoder connection
• All hoists can be double reeved
• Swivelling chain bag bracket for motor-down and motor-up use
• Multiple voltage motor
AETOS Range
Setting the other dip-switches
Dip-switch no 5 is set to "off" for a DC module and set to "on"
for a LV module.
Dip-switch no 6 is only set to "on" on the module at the end of
the flat-cable. Normally this is the module on the right hand
side. On all other modules dip-switch 6 must be set to "off".
Only 1 module can have dip-switch 6 set to "on".
10. CHANGING FROM 400V to 208/230V
The Aetos controllers are standard configured for a 3phase
400V power supply. The controllers can be adapted to accept
a power supply in the range of 208/230V.
In order to this adaptation it is only required to re-connect the
internal 24V power supply (named as 250U1 in the electrical
drawing) from Neutral and L1 to L2 and L1.
The controllers are suitable for both 50 and 60Hz frequencies.
It is advised to mark the controller on the outside at the mains
connector or the serial number sticker to show the new voltage
setting.
WARNING: Hoist running on 3x 208V will use the double
amount of current compared to hoists running on 3x 400V.

11. SPECIFICATIONS

The Prolyft Aetos controllers have the following general
specifications:
Power supply (standard)
Power supply (aYer adapZng)
Voltage range
Power connector
OperaZon temperature
Storage temperature
Link in/out
Max units to be linked (without
addiZonal spliders)
Length of link cable
Max power per channel
Output connector
Circuit breaker (per 4 channels)
12. DIMENSIONS
All units are 19-inch cabinets
Depth from front to back is 38,6cm.
Handgrips on the front need 3cm.
Connectors on the back need 5cm minimum.
Height for 4way unit is 3HE
Height for 8 and 12 way unit is 4HE.
page ! 9
400V, 3 phase, 50 or 60Hz
208/230V, 3 phase, 50 or 60Hz
+/- 10%
32Amp CEEform, 3ph+N+GND
+5 / +30 'C
-20 / +60 'C
Thuja network connecZon
6
99mtr (single cable)
1,5kW (400V)
HarZng 16pin
10Amp, C-characterisZc
WWW.PROLYTE.COM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents