Download Print this page

Technical Data; Menu Configuration; Output Of Measured Values - Bayrol PM5-SA4 User Manual

Plug-in module with 4 current outputs 4-20ma

Advertisement

PM5-SA4
5.
Now insert the aluminium rail at its original position. Take care
that the PM5-SA4 plug-in module is exactly located in the
corresponding slot of the aluminium rail as shown on the second
photo below.
6.
Remount the lid of the connection terminal box and close the
controller casing.
After completion and verification of the installation you can reconnect
mains power supply to the PoolManager
7

Technical data

Allowed ohmic resistance
of the connected current input
8

Menu Configuration

The configuration menu for the PM5-SA4 plug-in module is called up
as follows:
Menü-Hotkey
Communication & Interfaces
Submenu Current outputs 4-20mA:
controller.
®
Min.
Max.
400Ω
8.1

Output of measured values

Select the submenu for the current output of the desired
measurement, e.g. Current output pH.
The following parameters can be set in this menu:
Parameter
Possible
settings
Current output
Current output
pH / Cl / Br / mV / O2 / T1
1.1 / 1.2 / 1.3 /
1.4
(1)
Minimum value
Depends on measurement
(at 4 mA)
Maximum value
Depends on measurement
(at 20 mA)
Current output x.y means:
(1)
- x is the No. of the used plug-in connector
(usually this is plug-in connector 1)
- y is the No. of the current output
on the PM5-SA4 plug-in module
(2)
The default allocation is as follows:
- Current output 1.1:
pH
- Current output 1.2:
Cl or Br
- Current output 1.3:
mV or O2
- Current output 1.4:
Temperature T1
(3)
These Parameters can be used to adjust the desired measuring
range which is output on the 4-20 mA current output. The
minimum value always corresponds with the minimum current
signal of 4 mA; the maximum value corresponds with the
maximum current signal of 20mA.
The default settings are as follows:
Minimum. value
(at 4 mA)
pH
0,00 pH
Cl or Br
0,00 mg/l
mV
0 mV
O2
0 l
T1
0°C
Default setting
(default-set Europe)
Je nach Messgröße
(2)
(3)
(3)
Maximum value
(at 20 mA)
10,00 pH
10,00 mg/l
1000 mV
10 l
50 °C
7