Download Print this page

Installation; Opening The Casing - Bayrol PM5-SA4 User Manual

Plug-in module with 4 current outputs 4-20ma

Advertisement

PM5-SA4
6

Installation

This chapter describes the installation of the PM5-SA4 plug-in module
inside the PoolManager
®
controller and the cable connections.
Required user qualification:
ELECTRICAL SPECIALIST
Electrical connection may only be performed by an
ELECTRICAL SPECIALIST as defined in the chapter
User qualification of your PoolManager
manual.
6.1

Opening the casing

HAZARD DUE TO VOLTAGE!
Inside the controller you may get in touch with
dangerous electrical voltages.
Potential consequence: Death or the gravest
degree of injury.
Disconnect the controller from mains power supply
before opening the casing and, in particular, the lid of
the connection terminal box.
IMPORTANT NOTICE!
Open on the right
Never open the casing on the left side, as damage may
otherwise occur. Always open on the right side!
1.
Firmly press the hinge on the right side out and to the right.
®
or Analyt user
2.
Remove the cover plate and unhook the hinge on the bottom.
3.
Swing the casing cover open to the left.
4.
Unbolt the four screws of the lid of the connection terminal box
and remove the lid. Take out the aluminium rail afterwards.
5.
To close the casing, reverse this procedure.
5

Advertisement

loading

This manual is also suitable for:

127 011