Summary of Contents for Bayrol PM5-SA4
Page 1
PM5-SA4 Converter 4-20mA Version 1.1 User manual Plug-in module with 4 current outputs 4-20mA / Order No.: 127 011 Compatible with Analyt ® PoolManager ® PoolManager...
Please refer to the different user qualifications as defined in your PoolManager ® or Analyt user manual. Overview The PM5-SA4 Converter 4-20mA is a plug-in module for the BAYROL Measuring, Control und Dosing Systems PoolManager ® and Analyt of the 5th generation (from 2012). It provides 4 standard current outputs 4-20mA, which can be used to transmit the current measurement readings to external systems, e.g.
PM5-SA4 Installation Firmly press the hinge on the right side out and to the right. This chapter describes the installation of the PM5-SA4 plug-in module inside the PoolManager ® controller and the cable connections. Required user qualification: ELECTRICAL SPECIALIST Electrical connection may only be performed by an...
Now connect the cable ends to the connection terminals of the PM5-SA4 plug-in module. The digits 1 to 4 indicate the channel numbers which you can later select in the configuration menu.
1000 mV Allowed ohmic resistance 0Ω 400Ω 10 l of the connected current input 0°C 50 °C Menu Configuration The configuration menu for the PM5-SA4 plug-in module is called up as follows: Menü-Hotkey Communication & Interfaces Submenu Current outputs 4-20mA:...