5. Wait 5 minutes to clear out any gas. Then smell for gas
including near the floor. If you then smell gas, STOP!
Follow "B" in the safety information above. If you do
not smell gas, go to the next step.
6. Open manual shut-off valve (if so equipped) or the
valve at the outside propane tank. Correct operating
characteristics depend on the valve being positioned
fully open.
Never attempt to operate with a valve
partially closed.
NOTE: This furnace is equipped with a valve shut-off
switch. With switch in "OFF" position, gas will not flow to
burner nor will the furnace operate. See Figure 5.
7. Set thermostat to desired setting. If set above room
temperature, blower will come on.
BURNER OBSERVATION
WINDOW
A
B
ELECTRODE
D
C
BURNER ACCESS DOOR
HIGH YELLOW FLAME
FLAMME HAUTE JAUNE
SHARP BLUE FLAME
FLAMME AIGUE BLEUE
BURNER
CORRECT
FLAME
FLAMME
CORRECTE
COMBUSTION CHAMBER
CABINET
VALVE
GAS FITTING
SPARK WIRE
Figure 1
BEC
INCORRECT
FLAME
FLAMME
INCORRECTE
Figure 2
8. Allow 30 seconds for main burner to light after blower
turns on. This furnace is equipped with an ignition
device which automatically lights the burner. Do not try
to light the burner by hand.
9. If burner does not light, repeat Steps 1 through 9.
10. If after three (3) attempts with no ignition, go to shut
down and contact your dealer or a local recreational
vehicle service agency. Do not continue to cycle furnace
through thermostat in an attempt to get ignition.

TO SHUT DOWN

1. Set the thermostat to lowest setting, then move lever to
"OFF" position.
2. Turn off all electric power to the appliance if service is
to be performed.
3. Turn manual shut-off valve clockwise
position. Do not force.
TO CLEAN THE CHAMBER, THE FURNACE MUST BE REMOVED FROM
THE CABINET AND THE MANIFOLD BLOWER ASSEMBLY AND
CONTROLS REMOVED LEAVING THE CHAMBER ONLY, AS SHOWN.
USING COMPRESSED AIR BLOW THROUGH THE CHAMBER AS
SHOWN BY ARROWS, TO REMOVE SOOT OR LOOSE DEBRIS.
HANDLE IN "OFF" POSITION
MANETTE DANS LA POSITION ARRET (OFF)
VALVE SHOWN IN "OFF" POSITION
VALVE MONTREE DANS LA POSITION D ARRET (OFF)
4
to the "OFF"
Figure 3
MANUAL SHUT OFF VALVE
VALVE D ARRET MANUEL
Figure 4
ON/OFF SWITCH
MARCHE / ARRET
Figure 5

Advertisement

loading
Need help?

Need help?

Do you have a question about the Airxcel Suburban NT-16SEQ and is the answer not in the manual?

This manual is also suitable for:

Airxcel suburban nt-20seq