13. Recommendations

Protect the cable against external damage by using, for example, a mechanical shield (tube, mesh, etc.).
Align the two parts correctly so that the polar plate is centered with the suction pad. The polar plate is
equipped with a flexible system, it can be slightly compressed to guarantee a good contact.

14. Periodic Inspection

This product should be checked periodically at least once a year. To do this, simply execute a procedure
and record the results on a form. The following points must be checked:
Example of an assembly on a door:
Version E or R
Remove magnetic hold (pin 8): E = +24V, R = aloft
Move the transmitter 8 mm
SM1: Observe that the LED turns off
Check that contacts 1-5 and 4-6 are open
Check that contact 3 is closed (supply voltage)
Approach the transmitter at 4 mm
SM1: Observe that the LED lights up
Check that contacts 1-5 and 4-6 are closed
Check that contact 3 is open (no voltage)
Close door
Reactivate the hold (pin 8): E = aloft, R = +24V
EOP or ROP version
Remove magnetic hold (pin 8): E = +24V, R = aloft
Move the transmitter 8 mm
SM1: Observe that the LED turns off
Check that contacts 1-5 and 4-6 are open
Check that contact 3 is closed (supply voltage)
Approach the transmitter at 4 mm
SM1: Observe that the LED lights up
Check that contacts 1-5 and 4-6 are open
Check that contact 3 is open (no voltage)
Close door
Reactivate the hold (pin 8): E = aloft, R = +24V
Check that contacts 1-5 and 4-6 are closed
Check that contact 3 is open (no voltage)