Sm1 And Sm2; Benefits; Precautions For Use - COMITRONIC-BTI SM1 Series Instruction Manual

Electromagnetic interlocking for holding closed position of guards and doors of dangerous machines
Table of Contents

Advertisement

1. Benefits

SM1 Series
Electromagnetic holding of doors/casings of dangerous machines
ACOTOM magnetic field coding closure detection
Version E: sticking with power off [security access control]
Version R: sticking with power on [fire door, public access]
EOP version: sticking with power off acc. ISO 14119 [safety machine]
ROP version: sticking with power on and compatible with ISO 14119 [safety machine]
OX version: stainless steel 316L body and stainless steel suction cup : force up to 50 kg
PL version: PA6 body, steel suction cup: force up to 30 kg, stainless steel suction cup: force up to
50 kg
Automatic compatible lock/unlock command
Two safety contacts
An auxiliary output that indicates an open door or a default
LED which indicates the closing of the door and that the decoding of the transmitter is complete
Overheating protection with self-resetting device
Optional RFID pairing version: contact us for information
SM2 Series
Electromagnetic holding of doors/casings of dangerous machines
Version E: sticking with power off [access]
Version R: sticking with power on [fire]
EOP version: sticking with power off and compatible with ISO 14119 [machine]
ROP version: sticking with power on and compatible with ISO 14119 [machine]
Stainless steel 316L body and stainless steel suction cup: force up to 100 kg
ACOTOM
tamper-proof closure detection via coding
Automatic compatible lock/unlock command
Two safety contacts
An auxiliary output that indicates an open door or a default
Overheating protection with self-resetting device
Optional antibacterial door handle (EPB)
2. Cautions for Use
The polar plate of the transmitter and the suction cup of the receiver must be kept clean and must not
be damaged. For the version "sticking in off", the maximum duration of power is 10 min, we advise pla-
cing a control button near the door to limit the duration. The B22-CV-1OL-RGO-D3T10-BU-MKT touch
button performs the "open" function and limits the duration to 10 min:
- 1st support = delayed opening at 10 min
- 2nd support = closing (even if the duration has not elapsed)
SM1 AND SM2 SERIES
Hold and interlock
output
connection
diagnostic
M12
Connection
LED lighting
Receiver
Transmitter
redundant safety
contacts
polar spring plate
flexible 360 °
Handle
antibacterial
(optional)
overheating
protection
3