COMITRONIC-BTI SM1 Series Instruction Manual

COMITRONIC-BTI SM1 Series Instruction Manual

Electromagnetic interlocking for holding closed position of guards and doors of dangerous machines

Advertisement

Quick Links

COMITRONIC -
ELECTROMAGNETIC INTERLOCKING
FOR HOLDING CLOSED POSITION OF GUARDS
AND DOORS OF DANGEROUS MACHINES
stainless steel
50
Stainless steel version
OTHER PRODUCTIONS: FORCE 0 AND IP69K TOUCH BUTTON
Made in France
COMITRONIC-BTI THE LEADER IN STAND-ALONE SAFETY SWITCHES
contacts 2A/48V
2 million operations at
full load
BTI
INSTRUCTION MANUAL
SM1 AND SM2 SERIES
100
Plastic/steel
Plastic/steel version
new generation
Pld
SIL 2
CAT.3
3-year guarantee
INNOVATION IS OUR DRIVING FORCE
ADAPTABILITY IS OUR CULTURE
30

Advertisement

Table of Contents
loading

Summary of Contents for COMITRONIC-BTI SM1 Series

  • Page 1 Plastic/steel Stainless steel version Plastic/steel version OTHER PRODUCTIONS: FORCE 0 AND IP69K TOUCH BUTTON Made in France new generation COMITRONIC-BTI THE LEADER IN STAND-ALONE SAFETY SWITCHES SIL 2 contacts 2A/48V 2 million operations at full load CAT.3 3-year guarantee...
  • Page 2: Table Of Contents

    SM1 AND SM2 SERIES Hold and interlock CONTENTS SM1 and SM2___________________________________________________________________ 1. Benefits_______________________________________________________________ 2. Precautions for use _____________________________________________________ 3. Principle_______________________________________________________________ 3.1. Sticking with power off (machine) or sticking with power on (fire) _____________ 3.2. Interlocking __________________________________________________________ 4. Operation of OP versions________________________________________________ 4.1.
  • Page 3: Sm1 And Sm2

    LED lighting Receiver Transmitter Handle redundant safety antibacterial contacts (optional) 1. Benefits SM1 Series • Electromagnetic holding of doors/casings of dangerous machines  • ACOTOM magnetic field coding closure detection • Version E: sticking with power off [security access control] •...
  • Page 4: Principle

    SM1 AND SM2 SERIES Hold and interlock 3 . Principle 3.1 keeping the doors in the closed position (machine) or in the open position (fire) The electromagnetic lock acts as a safety sensor with a controllable hold using an electric control. We have the advantage of offering both types of interlock, in off or on position.
  • Page 5: Operation Of Versions E And R

    Process Machine safety Recommended for machine safety ISO 14119 Comitronic-Bti suction cups offer a wide range of choices to the customer. The steel versions are very competitive while the stainless steel versions offer great performance of holding force in harsh envi- ronments.
  • Page 6: Main Features

    SM1 AND SM2 SERIES Hold and interlock 7. Main Features PL-AC Supply voltage 21.6 VDC to 26.4 VDC Power supply without magnet action 40 mA to 24 VDC Power supply with magnet action Type E 670 mA 0.21 A 1.35 A Type R 150 mA 0.075 A...
  • Page 7: Sm1 Model Dimensions

    SM1 AND SM2 SERIES Hold and interlock 9. SM1 Model Dimensions10. SM2 Model Dimensions F4.3 20.5 31.5 R > 50 R > 50 11. EPB handle dimensions (optional item) Antibacterial handle...
  • Page 8: Complete Solution Of Interlocking Machine With Inertia

    Complete solution of interlocking machine with inertia Equipment for this installation: SM1-OX-EOP-OX-FL (interlocking) AWAX26XXL (monitoring, on/off management) B22-CV-1OL-RGO-D3T10-BU-MKT (opening command) SPEEDTRONIC (zero speed control) FKT: 5 m, 10 m or 15 m (connection) FKT cord 1 5 4 6 open 200 mA...
  • Page 9: Recommendations

    SM1 AND SM2 SERIES Hold and interlock 13. Recommendations Protect the cable against external damage by using, for example, a mechanical shield (tube, mesh, etc.). Align the two parts correctly so that the polar plate is centered with the suction pad. The polar plate is equipped with a flexible system, it can be slightly compressed to guarantee a good contact.
  • Page 10: Item Code

    Serial number coding & example YEAR WEEK NAME OPERATOR / NAME TEST MANAGER POSITION Name of Technical Authority: Christophe Pays of COMITRONIC-BTI This product range is intended to monitor an emergency stop or safety sensor. The safety modules are designed and manufactured according to UL508 / CSA C22.2 Regu- lation.
  • Page 11 COMITRONIC - 14 Rue Pierre Paul de Riquet 33610 Canéjan +33 5 64 10 04 52 www.comitronic-bti.com SMEN_250618_v0.0...

Table of Contents