SBP4K8 Battery Testing
Battery Connection
To test whether the battery is connected to your system properly, ensure the DC
power cables are firmly connected to the inverter terminals.
Make sure the data cables (labelled as CANH and CANL) are connected at CANH
and CANL port of the inverter. Pull the data cables gently to ensure the cables are
placed at the CANH and CANL slot of the inverter (Figure 1).
Figure 1 Battery communication cable at the inverter terminal
Please ensure the 'Battery Type' and 'Battery Quantity' has been entered correctly
on the inverter menu. To set up the Battery on the inverter menu, firstly Key Stop the
inverter. Now navigate to Main Menu → Select Settings → Enter Password 111 →
Select Battery Type and Battery Quantity (Figure 2).
Figure 2 Battery type and battery quantity
Please power on the inverter, the LCD screen on the inverter should now display the
battery as connected (Figure 3, left). If the battery is not connected properly the LCD
screen will display '--' on the battery side (Figure 3, right).
Figure 3 Battery connected (left) and Battery not connected (right)
TD_201806_SBP4K8_Battery Testing_V1.0
Page 1 of 4
© Sungrow Australia Group Pty. Ltd. All rights reserved.
The information in this document is subject to change without notice.

Advertisement

loading

Summary of Contents for Sungrow SBP4K8

  • Page 1 Sungrow Australia Group Pty. Ltd. | 1800 SUNGROW (786 476) service@sungrowpower.com.au www.sungrowpower.com.au SBP4K8 Battery Testing Battery Connection To test whether the battery is connected to your system properly, ensure the DC power cables are firmly connected to the inverter terminals.
  • Page 2 Sungrow Australia Group Pty. Ltd. | 1800 SUNGROW (786 476) service@sungrowpower.com.au www.sungrowpower.com.au If the LCD screen on the inverter shows ‘--’ on the battery side, please re-check the wiring (especially the data cables). If the status on the inverter screen shows ‘Error’, check the error code on the inverter menu.
  • Page 3 Sungrow Australia Group Pty. Ltd. | 1800 SUNGROW (786 476) service@sungrowpower.com.au www.sungrowpower.com.au Figure 5 Battery terminals inside the inverter If the battery is not connected properly or powered off, the voltage reading on the battery terminal inside the inverter may display around 20V, which is from the inverter circuit board.
  • Page 4 (44.8V – 58.1V), check the battery information from the main menu-run info (Figure Figure 9 Run info – Battery information Check the battery SOC (state of charge), SOH (state of health) and battery voltage. To watch the installation tip for SBP4K8 battery, please click here. TD_201806_SBP4K8_Battery Testing_V1.0 Page 4 of 4 ©...