4.8.6 MTS CIRCUIT
Measuring
Item
instrument
MTS INPUT
Remote
LEVEL
control unit
MTS
TV audio
SEPARATION
multiplex
signal
generator
Oscilloscope
Remote
control unit
L-Channel
signal waveform
1 cycle
1-40 (No.YA093)
Test point
Adjustment part
[1.PICTURE/SOUND]
A01: IN LEVEL
R OUT
[1.PICTURE/SOUND]
L OUT
A02: LOW SEP
[AUDIO OUT]
A03: HI SEP
R-Channel
crosstalk portion
Minimum
Description
(1) Receive the any broadcast.
(2) Select the 1.PICTURE/SOUND from the SERVICE
MODE.
(3) Select the < A01 > (IN LEVEL).
(4) Set the intal setting value of the < A01 >.
(5) Press the [MUTING] key to memorize the set value.
(1) Input the stereo L signal (300Hz) from the TV audio
multiplex signal generator to the antenna terminal.
(2) Connect an oscilloscope to L OUT pin of the AUDIO
OUT, and display one cycle portion of the 300Hz
signal.
(3) Change the connection of the oscilloscope to R OUT
pin of the AUDIO OUT, and enlarge the voltage axis.
(4) Select 1.PICTURE/SOUND from the SERVICE
MODE.
(5) Set the initial setting value of the < A02 > (LOW
SEP).
(6) Adjust the < A02 > so that the stroke element of the
300Hz signal will become minimum.
(7) Change the signal to 3kHz, and similarly adjust the
< A03 > (HI SEP).
(8) Press the [MUTING] key to memorize the set value.