Quality of wood pellets:
Depending on the manufacturer there are light, dark, shorter and longer pellets. And the quality of one delivery may
differ from another even from the same supplier. The standards for wood pellets are becoming more and more strict
but wood is wood and has its own characteristics regarding ash and clinker.
Cleaning requirements:
As soon as you find ash and clinker deposits in the cold combustion pot, it must be cleaned. See operating
instructions! If this is not done, there will be more and more clinker. Then the device will no longer be able to ignite
properly. Pellets may pile up in the combustion pot. In extreme cases, this can reach all the way back to the pellet
chute. Backfire in the pellet container and smouldering in the pellet tank might possibly result. This will destroy
your device and is not covered by the guarantee.
For maximum working life:
Arrange for commissioning by your trained stove supplier.
Observe the daily check as described and more frequently if you have received new pellet deliveries or when
the device is brought back into use after the summer.
Carefully read through all the operating instructions and retain them.
Type number:
Important manufacturer's instructions
Equipment sheet - Pellett Stove
Art. no. 0541908109030
V16 G27
Pelletto III
419.08 / 434.08
!

Advertisement

Table of Contents
loading

Summary of Contents for Haas+Sohn Pelletto III 419.08

  • Page 1 Art. no. 0541908109030 V16 G27 Pelletto III 419.08 / 434.08 Equipment sheet - Pellett Stove Important manufacturer’s instructions Please observe the following instructions: Quality of wood pellets: Depending on the manufacturer there are light, dark, shorter and longer pellets. And the quality of one delivery may differ from another even from the same supplier.
  • Page 2: Table Of Contents

    Index of contents Cleaning and maintenance work 1.1. Cleaning the surface 1.2. Cleaning the glass panel 1.3. Clean combustion chamber “function instruction” Error F040 1.4. Cleaning the combustion pot –weekly 1.5. Cleaning the pellet container - annual maintenance 1.6. Cleaning the flue gas passes - annual maintenance 1.7.
  • Page 3: Cleaning And Maintenance Work

    1.2. Cleaning the glass panel 1. Cleaning and maintenance work The functioning of your device depends to a large extent To clean the viewing panel, you must first open the on regular expert maintenance. Because of the ash stove door. Dirt on the glass panel can be removed with accumulation resulting from the combustion of wood a glass cleaner or with a damp sponge on which you pellets, constantly recurring cleaning and maintenance...
  • Page 4: Cleaning The Pellet Container - Annual Maintenance

    1.5. Cleaning the pellet container - annual maintenance Heat the pellet stove until the storage tank is completely empty. Then the protective grille (1) in the pellet tank may be removed. Then clean the tank and the intake of the screw conveyor housing with a vacuum cleaner. After cleaning, it is essential to put back the protective grille.
  • Page 5: Cleaning The Flue Gas Passes - Annual Maintenance

    1.7. Cleaning the induced draught housing and fan 1.6. Cleaning the flue gas passes - annual This housing is made accessible for cleaning by undoing maintenance the 4 nuts shown in Figure 5. (See arrows). First pull the stove away from the wall so as to create Remove the induced draught motor by pulling it out.
  • Page 6 Figure 4b: Removing the side wall Pelletto III: 419.08, 434.08 Pelletto III: 419.08C, 434.08C After completion of the cleaning make sure that when putting back the covers, the seals are seated in the right positions. It is essential to replace defective seals.
  • Page 7: Technical Data

    2. Technical data Pelletto III 419.08 Pelletto III 434.08 Heat output range: 2,4 – 8,3 kW 2,4 – 8,3 kW Nominal heat output 8,0 kW 8,0 kW Height: 1001 mm 1193 mm Width: 557 mm 557 mm Depth: 493 mm...
  • Page 8 Figure 6: Dimensions of Pelletto III 419.08 Pelletto III 419.08-C...
  • Page 9 Figure 7: Dimensions of Pelletto III 434.08 Pelletto III 434.08-C...
  • Page 10 Figures 8: Replacement parts Pelletto III 419.08 Pelletto III 419.08-C...
  • Page 11 Figures 9: Replacement parts Pelletto III 434.08 Pelletto III 434.08-C...
  • Page 12: Replacement Parts List

    3. Replacement parts list 419.08 419.08 C 434.08 434.08 C Front plate anthracite 0541908006120 0541908006120 0543408006120 0543408006120 Front plate grey 0541908016120 Complete combustion chamber door anthacite 0541908005300 0541908005300 0541908005300 0541908005300 Complete combustion chamber door grey 0541908015300 Door hinge anthracite 0551908005410 0551908005410 0551908005410 0551908005410...
  • Page 13: Circuit Diagram

    4. Circuit diagram...
  • Page 14 No.: Description Cable harness Mains plug / mains filter Electric ignition Screw conveyor motor Induced draught 35/36 Flue gas temperature sensor 37/38 Flame temperature sensor 39/40 Room temperature sensor 41/42 Bottom flame temperature sensor 43/44 Door contact switch 48-50 Flue gas fan rotation speed Fuse T 3,15A ignition, induced draught fan, screw conveyor motor Fuse T 0,315A operator console...
  • Page 15 Slow combustion stoves and auxiliary ranges for wood, coal and oil Fireplace inserts for wood Accessories for stoves and fireplaces Accessories for central oil supply HAAS+SOHN Sales in Germany OFENTECHNIK GMBH HAAS+SOHN Ofentechnik GmbH Urstein Nord 67 Zur Dornheck 8 A-5412 Puch D-35764 Sinn - Fleisbach Email: office@haassohn.com Email: info@haassohn.com...